Top
Systemwalker Operation Manager Troubleshooting Guide
FUJITSU Software

A.2.2 UNIX Versions

The content described here is for the following:

Result if the maintenance information could not be collected

In Solaris, if collection of the maintenance information fails, the following is displayed:

# ./swcolinf -i tool -o /export/home
Collecting TRACE information...
Collecting FJSVftlo information...
Collecting installer information...
Collecting COMMON information...

*** INFORMATION ***
Could not collect the following files due to errors such as out of space
Copy these files manually to an appropriate location for each function.

[FJSVftlo]
/etc/opt/FJSVftlo/trc/etc/f3cvgtad.ini

Storage location: /export/home/OperationManager/0005/FJSVftlo

*The following file also has the above information.
/export/home/OperationManager/0005/swcolinf.log

Systemwalker Operation Manager information has collected successfully
Storage location: /export/home/OperationManager/0005
#

Point

The same result will also be stored in the following log file:

<information storage directory>/OperationManager/<generation number>/swcolinf.log

Action method

Manually copy the file for each function displayed in the output result to the storage directory per function.