Error message
Monitoring server is down due to an internal error. The client will exit. |
Applicable versions and levels
Windows versions: V11.0L10 or later
Solaris versions: 11.0 or later
Linux versions: V11.0L10 or later
Linux for Itanium versions: V12.0L10 or later
HP-UX versions: 11.0 or later
AIX versions: 5.1 or later
Action
Cause
Possible causes are as follows:
The network was disconnected temporarily during communication between the Systemwalker Operation Manager server and client.
The Systemwalker Operation Manager server stopped during the connection.
Action method
Perform the following tasks according to the cause:
If there is a problem in the network, review the network. By reconnecting the client, the client window will be displayed.
If the Systemwalker Operation Manager server has stopped, start the Systemwalker Operation Manager server and then reconnect the client.