Applicable versions and levels
Windows versions: V5.0L10 or later
Solaris versions: 5.0 or later
Linux versions: 5.2, V10.0L10 or later
Linux for Itanium versions: V12.0L10 or later
HP-UX versions: 5.1 or later
AIX versions: 5.1 or later
DS versions: V20L10
Action 1
Points to check
Was "Restart point" set for the top job?
Action method
On the Control information tab in the Monitor - Job window, check the "Restart point" setting, and review the setting if necessary.
Action 2
Points to check
After the job net ended abnormally, was the registration information for the job changed?
Cause
If the registration information for the job was changed, the job net and job will be reset to the "Waiting" status. For this reason, even if the restart operation is performed, all jobs will be executed.
Action method
V11.0L10/11.0 or later
To change only the registration information for the job, without changing the status of the job net and job, change the job information using change recovery.
Alternatively, after changing the job information, perform the disable operation for the job you do not want to execute, and then "Restart" the job net.
V10.0L21/10.1 or earlier
After changing the job information, perform the disable operation for the job you do not want to execute, and then "Restart" the job net.
Information
Refer to the following for a description on the "Disabled" status:
"4.3.2 Although the Job Flow Execution Proceeds in the Monitor Job Net window, when the Job Execution Result is Checked, it seems that the Job has not been Started" in "4.3 The Job Behavior is Abnormal"