Top
Systemwalker Operation Manager Troubleshooting Guide
FUJITSU Software

4.2.6 A Job Net that should have Started Starts Again

Applicable versions and levels

Action 1

Points to check

Was Valid during job net execution selected in the Message tab in the Job Net Properties window?

Cause

If the Valid during job net execution check box is selected, and a message event that is waited for is generated while the job net is executing, the job net restarts immediately after it has ended.

Action method

Review the Job Net Properties >> Message settings.

Action 2

Points to check

Was the job net execution condition set to execute the job net multiple times?

Action method

Review the Job Net Properties >> Standard information settings.

If multiple times were specified for Execute at, or Interval was specified, review the specified content and ensure that it is correct.