1.2.8 Support Levels

The scope of the storage management functions of this software that can be used varies with the storage device model being used. For this software, the scope of available functions is represented as support levels, which are used as settings of the fault monitoring function and for other purposes. The table below lists the support levels that can be selected.

Table 1.4 Support Levels

Support Level

Typical Device Name

Device Detection

Fault Management

Management Window Linkage

Performance Management

SNMP Trap Monitoring

Device Polling Monitoring (*1)

Acquisition of Device State

A

ETERNUS DX series
ETERNUS SN200 (except model 250M)
ETERNUS PRIMERGY BX600 Fibre Channel switch blade
Brocade series
Brocade VDX series (except VDX 8770-4/VDX 8770-8) (*5)(*8)(*9)
PRIMERGY BX Ethernet Fabric Switch (*5)(*8)

Automatic
(*2)

Y1

Y1

Y1

Y1

Y1
(*6)

B

Solaris OS, Windows, Linux, HP-UX, AIX server node on which Storage Cruiser's agent is already installed
ETERNUS LT250/LT270 (*5)
Brocade VDX 8770-4/VDX 8770-8

Automatic
(*2)

Y1

Y1

Y1

Y1

-

C

VMware vSphere 4 or later

Automatic
(*2)

-

Y1

Y1

-

-

D

NetApp FAS Series
NetApp V-Series

Manual

Y1
(*5)

Y1

-

Manual setting

Y1
(*7 For data collection only)

E

ETERNUS LT20/LT20 S2
ETERNUS LT40/LT40 S2
ETERNUS LT60/LT60 S2
ETERNUS LT200
ETERNUS LT210
ETERNUS LT220
ETERNUS LT230
ETERNUS LT270 S2
ETERNUS VS850

Manual

Y1
(*5)

Y1

-

Manual setting

-

ETERNUS CS800
ETERNUS CS2000

Manual

Y1
(*5)

Y1

-

-

-

H

ETERNUS SN200 model 250M

Manual

Y1
(*5)

Y1

-

Manual setting

-

I

Other devices that are manually embedded

Manual

-
(*3)

-
(*4)

-

Manual setting

-

Y1: Detail information on device internal elements can be displayed.
*1: The protocols using in the device polling are as follows.

Typical Device Name

Protocol Name

ETERNUS DX series
ETERNUS SN200 (except model 250M)
PRIMERGY BX600 Fibre Channel switch blade
Brocade series
Brocade VDX series
PRIMERGY BX Ethernet Fabric Switch

SNMP

Server node on which Storage Cruiser's agent is already installed

unique protocol

VMware vSphere 4 or later

VMware dedicated protocol

Other than listed above

ping

*2: The "Detect device in subnet" function is not supported by the devices below. Specify and register the IP addresses.

*3: For devices supporting SNMP Traps, this function is enabled by creating a SNMP Trap XML definition file.

*4: For devices supporting LAN, ping monitoring is enabled by specifying an IP address at manual embedding.

*5: SNMP Trap transmission must be set for each device. (This software does not automatically make said setting.)

*6: There are concerns in performance information. Refer to the Note in "7.1.1 Performance Information Types".

*7: For NetApp FAS Series. To refer to the performance information that is collected on the NetApp FAS Series, must be linkage with Systemwalker Service Quality Coordinator. Contact Fujitsu Technical Support for details on performance information.

*8: Only as for devices whose firmware version number is 3.0.1 or later, the performance management function is supported.
*9: The automatic registration function is not supported for devices whose firmware version number is 4.0. Revise the firmware version or register manually.