6.1.9 Reload ETERNUS Disk Storage System Configuration Information

The procedure to reload the ETERNUS Disk storage system configuration information is as follows:

  1. On the global navigation tab, click Storage.
    The registered ETERNUS Disk storage systems are displayed on the Main pane.

  2. On the Main pane, check the target ETERNUS Disk storage system checkbox.

  3. On the Action pane, click Reload Conf. under Storage.

Point

ETERNUS SF Manager updates the displayed information, obtaining the information from the ETERNUS Disk storage system section by section. If any of the situations below have occurred, perform the above-described operation to display the up-to-date information.

  • Changed the configuration using ETERNUS Web GUI. (*1)

  • Changed the configuration using CLI. (*1)

  • Check the status of the constituted elements because of trouble in the ETERNUS Disk storage system.

  • Clear the Error status after the recovery because of trouble in the ETERNUS Disk storage system.

*1: For the following devices, the configuration information excluding performance management configuration information and the information related to Automated Storage Tiering is automatically reflected, so the above-mentioned operation is not required.

  • ETERNUS DX80 S2/DX90 S2 (firmware version V10L40 or later)

  • ETERNUS DX100 S3/DX200 S3 (all firmware versions)

  • ETERNUS DX400 S2 series (firmware version V10L40 or later)

  • ETERNUS DX500 S3/DX600 S3 (all firmware versions)

  • ETERNUS DX8000 S2 series (firmware version V10L40 or later)

Note

The reloading of ETERNUS Disk storage system configuration information may take from a few minutes to over 10 minutes depending on the device configuration. The Job Status pane allows you to confirm the completion of ETERNUS Disk storage system configuration information reloading. However, since the information in the Job Status pane is automatically deleted 24 hours after processing is completed, check deleted information in "11.1 Display Operation History". The ETERNUS Disk storage system configuration information reloading has completed when the displayed items of the Operation History screen is as follows:

  • Action: Reload Configuration on Disk Array

  • State: Complete

  • Result: Success

  • Target: Name of the registered ETERNUS Disk storage system

Please do not perform any operation for this ETERNUS Disk storage system until the configuration information reloading has been completed.