Message ID
(Error type)

Item

Description

VSYS40300
(ERROR)

Message

Template does not exist. Template-ID=[{0}]

Description

The template ID does not exist.
{0} is the template ID.

Action

Check if the template ID is correct, and then try again.

VSYS40301
(ERROR)

Message

Template-ID is already used. Template-ID=[{0}]

Description

The template ID is already being used.
{0} is the template ID.

Action

The template ID is being used by the information for saving a configuration. Delete the information, and then try again.

VSYS40302
(ERROR)

Message

Server-No does not exist in the Template. Template-ID=[{0}], Server-No=[{1}]

Description

The server serial number does not exist.
{0} is the template ID.
{1} is the server serial number.

Action

Check whether the server number specified in the software option is correct, and then try again.

VSYS40303
(ERROR)

Message

Software-ID does not exist in the Image. Image-ID=[{0}], Software-ID=[{1}]

Description

There is no association between the ID of the template where the software ID is specified and the image ID registered with the server serial number.
{0} is the image ID.
{1} is the software ID.

Action

Check whether the software ID specified in the software option is included in the image information for the server. Then try again.

VSYS40304
(ERROR)

Message

ParameterInfo does not exist. ParameterInfo-ID=[{0}]

Description

The parameter information does not exist.
{0} is the parameter ID.

Action

Check if the parameter information ID is correct.
If the error persists, contact Fujitsu technical support.

VSYS40305
(ERROR)

Message

SoftwareSetup-ID is not related to Software-ID. Software-ID[{0}], SoftwareSetup-ID=[{1}]

Description

The software setup information for the parameter information does not match the software setup information associated with the software.
{0} is the software ID.
{1} is the software setup ID.

Action

Check whether the software ID and the parameter ID are correct, and then try again.

VSYS40306
(ERROR)

Message

SQL error occurred. method=[{0}]

Description

An SQL error has occurred.
{0} is the SQL statement that contains an error.

Action

Check whether the RDB system is running normally.
If the error persists, contact Fujitsu technical support.

VSYS40320
(ERROR)

Message

Parameter information does not exist. no=[{0}] softwareId=[{1}] parameterInfoId=[{2}]

Description

The parameter ID for the software option specified in the template does not exist in the parameterInfo table.
{0} is the server serial number.
{1} is the software ID.
{2} is the parameter ID.

Action

Check the parameter ID for the software option in the template information, and then try again.

VSYS40321
(ERROR)

Message

SoftwareID does not exist in image. no=[{0}] imageId=[{1}] softwareId=[{2}]

Description

The software for the software option specified in the template is not included in the software for the image.
{0} is the server serial number.
{1} is the image ID.
{2} is the software ID.

Action

Check the software ID for the software option in the template information, and then try again.

VSYS40322
(ERROR)

Message

Parameter information and software setup infomation not link . no=[{0}] softwareId=[{1}] parameterInfoId=[{2}]

Description

The parameter information for the software option specified in the template has not been specified in the software setup information for the software.
{0} is the server serial number.
{1} is the software ID.
{2} is the parameter ID.

Action