This section describes how to change the settings of the shutdown facility when changing the settings of the host OS in the environment where the virtual machine function is used with PRIMEQUEST1000 series.
The following describes how to change the settings when you have changed the guest OS user password from the host OS after introducing the PRIMECLUSTER system into a virtual machine environment.
Operation procedure
Execute the following command on all guest OSes (nodes) to stop the operation of the shutdown facility (SF).
# sdtool -e
Encrypt the password.
# /opt/SMAW/SMAWsf/bin/sfcipher -c Enter Password: Re-Enter Password: Xh+kSlJ8nlQ=
Define the encrypted password in the Shutdown Agent configuration file.
See
For details on how to define the configuration file, see "5.1.2.4.3 vmSP (Virtual Machine Service Provider)."
Execute the following command on all nodes to start the shutdown facility (SF).
# sdtool -b
The following describes how to change the settings when you have changed the Host OS IP address of the administrative LAN with the MMB after introducing the PRIMECLUSTER system into a virtual machine environment.
Operation procedure
Execute the following command on all nodes to stop the operation of the shutdown facility (SF).
# sdtool -e
Define the changed IP address in the Shutdown Agent configuration file.
See
For details on how to define the configuration file, see "5.1.2.4.3 vmSP (Virtual Machine Service Provider)."
Execute the following command on all nodes to start the shutdown facility (SF).
# sdtool -b