Top
ServerView Resource Orchestrator Cloud Edition V3.1.1 Setup Guide
ServerView

B.3.1 Automatic Network Configuration

If network resources are connected when creating an L-Server, LAN switch blades will be registered automatically as the blade server that the L-Server will operate on.

If an image is specified, the IP address is configured.
Specify an IP address in a different subnet from the admin LAN.

For rack mount and tower servers, only connect network resources.

When creating a physical L-Server, the IP address cannot be automatically configured if specifying a Red Hat Enterprise Linux image.
Manually configure the IP address after the image has been deployed to the L-Server.


Physical Server (Blade Server) Configuration to Support Automation of Network Configuration in Resource Orchestrator

The physical server (blade server) configuration to support automation of network configuration (server blades, specification of uplink port for network resources, correspondence relations of numbers of LAN switch blades and physical network adapters, etc.) in Resource Orchestrator are shown in the following list. In this list, show the specifiable scope of physical network adapter numbers according to the server blade models, uplink port specifications and combination of LAN switch blades to use.

Table B.3 Physical Server (Blade Servers) Configuration (for PRIMERGY BX900 S1 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number

BX920 S1
BX920 S2
BX920 S3
BX922 S2
BX924 S3

CB1 and CB2, or no specification for uplink port

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

1 - 4

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109) (*1)
PY-CNB101 (*2)

1,2

CB3 and CB4

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

5 - 8

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109)
PY-CNB101

5,6

BX924 S2

CB1 and CB2, or no specification for uplink port

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)

1,2

CB3 and CB4

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

3 - 6

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109)
PY-CNB101

3,4

BX960 S1

CB1 and CB2, or no specification for uplink port

PY-SWB101(PG-SW201)
PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)
PY-SWB104(PG-SW109)

1, 2, 11, 12

CB3 and CB4 (*3)

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

3 - 6

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109)
PY-CNB101

3,4

*1: When installing a PY-SWB104 (PG-SW109) on CB1 or CB2, set the transmission speed at the down link port of PY-SWB104 (PG-SW109) to 1 Gbps. For details on how to configure the settings, refer to the corresponding hardware manual.
*2: Only BX920 S2 and BX924 S3 are supported as server blades, when mounting PY-CNB101 on CB1 and CB2.
*3: Only configurations where LAN expansion cards are mounted in expansion slot 1 are supported.


Table B.4 Physical Server (Blade Servers) Configuration (for PRIMERGY BX400 S1 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number

BX920 S2
BX920 S3
BX922 S2
BX924 S3

CB1 and CB2 (*1), or no specification for uplink port

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

1 - 8

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109) (*2)
PY-CNB101 (*3)

1, 2, 5, 6

BX924 S2

CB1 and CB2 (*1), or no specification for uplink port

PY-SWB102(PG-SW111)
PY-SWB103(PG-SW112)

1 - 6

PY-SWB101(PG-SW201)
PY-SWB104(PG-SW109)

1 - 4

*1: The same LAN switch blade model should be mounted in CB1 and CB2.
*2: When installing a PY-SWB104 (PG-SW109) on CB1 or CB2, set the transmission speed at the down link port of PY-SWB104 (PG-SW109) to 1 Gbps. For details on how to configure the settings, refer to the corresponding hardware manual.
*3: Only BX920 S2 and BX924 S3 are supported as server blades, when mounting PY-CNB101 on CB1 and CB2.


Table B.5 Physical Server (Blade Servers) Configuration (for PRIMERGY BX600 S3 Chassis)

Server Blade

Specification of Uplink Port
(Location of LAN Switch Blade)

LAN Switch Blade to Use

Physical Network Adapter Number

BX600 series servers

NET1 and NET2, or no specification for uplink port

PG-SW107

1 - 6

NET3 and NET4

PG-SW104

7,8


The NIC number of the L-Server the network resource above is allocated to is the number of the physical network adapter of the physical server.

When the LAN switch blade is in IBP mode, specify the NIC of the L-Server that network resources are allocated to as in the case when uplink ports have not been specified (internal network).


The physical server (blade server) configuration as described in the following configuration example when using a PRIMERGY BX900 S1 chassis is as shown below.

Table B.6 Configuration Example

Server blades

BX920 S2

Specification of uplink port

CB1 and CB2

LAN switch blade to use

PY-SWB103(PG-SW112)

Figure B.1 Physical Server (Blade Servers) Configuration (for PRIMERGY BX900 S1 Chassis)