Explanation
There is no session for the specified copy pair.
System action
The system terminates processing.
System administrator response
Operations cannot be executed on copy pairs for which there is no copy session.
Check the session status using either acopc query command or acec query command.
Refer to the ETERNUS SF Operation Guide for Copy Control Module for information on the command.
Explanation
Either the access volume specified at ETERNUS Disk storage system registration time or the device name specified using a command is invalid.
System action
The system terminates processing.
System administrator response
Check that the specified device name is correct.
Or, the access volume may have been disabled.
Check the drive letter and device name specified in the access volume, and set a valid access volume.
The acarray pathscan command can be used to set the access volume automatically.
Refer to the ETERNUS SF Operation Guide for Copy Control Module for information on the command.