3.7.2 Changing Input Values Set in the Automatic Operation Process

The following settings are required for the automatic operation process:

User-defined attributes

Values must be set in the user-defined attributes of the automatic operation process. Enter values as shown below.

Table 3.5 Automatic operation process user-defined attributes

User-defined attribute name

Input value

Use

smtp_server

Host name or IP address of the mail send (SMTP) server

Used as the hostname parameter value of the operation part that sends error mail

from_address

Error mail send source address

Used as the fromaddress parameter value of the operation part that sends error mail

to_address

Error mail send destination address

Used as the toaddress parameter value of the operation part that sends error mail

hostname

Host name or IP address of the server targeted for operation confirmation

Used as the hostname parameter value of the operation part that confirms the power supply status and the operation part that confirms the operating status

event_manager

Host name or IP address of the operation management server

Used as the hostname parameter value of the operation part that confirms event issue

event_message

Event message character string used to confirm that the system is operating normally

Used as the eventmessage parameter value of the operation part that confirms event issue

manager_server

Web console URL host name to be coded in the mail text to be sent

Used to code the Web console URL in the text parameter value of the operation part that sends error mail

Operation part input information

If required, set a parameter value as input information for the following operation part:

Enter parameter values as shown below.

Table 3.6 Operation part input information

Operation part name

Parameter name

Input value

Send error mail 1-3

smtpusername (*1)

User name for SMTP authentication to the host of the mail send (SMTP) server

smtppassword (*1)

User password for SMTP authentication to the host of the mail send (SMTP) server

*1:
Set this parameter in environments that require authentication to the SMTP server when mail is sent.

Delay node timer value

Set times for the delay node timers, as required. The settings contents are shown below.

Table 3.7 Timer settings information

Name

Timer name

Settings value

Delay_morning

morningtimer

The time when operation confirmation is to be performed.
"09:00" is set as the default.

Delay_afternoon

afternoontimer

The time when operation confirmation is to be performed.
"12:00" is set as the default.

Delay_evning

eveningtimer

The time when operation confirmation is to be performed.
"18:00" is set as the default.


See