Top
ServerView Resource Orchestrator V3.1.0 Messages
ServerView

17.4 Messages PCS3000 to PCS3003

This section explains messages starting from PCS3000.


PCS3001

Description

An exception occurred in ModelAPI of the application process.

Corrective Action

Check a detailed message and execute the following correspondences.

  • When WFServerException occurred

    It is not possible to connect to Systemwalker Runbook Automation. Check whether Systemwalker Runbook Automation starts.

  • When ModelInternalException occurred

    Failed to make the process instance.
    In case the detail message includes VSYSAPIConnectionException, check if L-Platform Management function is started and if it can be connected.
    If VSYSAPIResponseException appears in the message details, check "Chapter 20 Messages Starting with VSYS" for the error content and take the indicated action.

  • Case other than the above

    Contact Fujitsu technical support.

PCS3002

Description

The application process setting file contains an error.

Corrective Action

Check if the application process setting file contains an error.

[Windows Manager]

Installation_folder\RCXCTMG\MyPortal\config\application_process.properties

[Linux Manager]

/etc/opt/FJSVctmyp/config/application_process.properties

PCS3003

Description

The process definition contains an error.

Corrective Action

Check the application processes configuration file in the following.

[Windows Manager]

Installation_folder\RCXCTMG\MyPortal\config\application_process.properties

[Linux Manager]

/etc/opt/FJSVctmyp/config/application_process.properties