This section explains the 613XX message series.
Description
An internal error has occurred.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
Boot monitoring of the managed server failed.
Processing of the WWN settings for the HBA of the server may fail.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
Control of the PXE server failed.
Processing of the WWN settings for the HBA of the server may fail.
Corrective Action
Collect troubleshooting information and contact Fujitsu technical staff.
Description
The process of setting the WWN for the HBA of the server failed.
An internal code is displayed for %1.
One of the following is indicated for %2:
HBA adapter not found
command error
TFTP error
Corrective Action
Make sure the total number of ports on HBA adapters mounted on the server is equal to or greater than the number specified on the GUI.
For Virtual Edition, refer to "6.2.7 BIOS Settings of Managed Servers" in "Design Guide VE" and update the FC-HBA BIOS firmware if it is old.
For Cloud Edition, refer to "8.2.7 BIOS Settings of Managed Servers" in "Design Guide CE" and update the FC-HBA BIOS firmware if it is old.
A problem related to file transfer has occurred. Check the status of the admin LAN.
Check that the IP address of the admin LAN for the managed server and other IP addresses (such as the admin LAN of iRMC or SAN storage) do not overlap.
When a message other than the above is output, or the corrective action above does not resolve this problem, collect troubleshooting information and contact Fujitsu technical staff.
Description
The port number used for service_name is already in use.
Corrective Action
Check the port number used by service_name, and change it if necessary.
For details, refer to "Appendix A Port List" in the "Design Guide VE" and "Design Guide CE".