Top
PRIMECLUSTER GLS for Windows User's Guide 4.3

4.1.2 Stopping the System

GLS stops automatically when Windows shuts down, but virtual adapters remain activated.

If necessary, for example if you need to change virtual adapter settings, you can use the stphanet command to deactivate virtual adapters. Log in as a member of the Administrators group before executing the stphanet command.

The following example shows how to execute the stphanet command and gives a sample result.

> stphanet
FJSVhanet: INFO: 00005: The ping monitoring stopped.
FJSVhanet: INFO: 00000: The command ended normally.

For more details on the stphanet command, refer to "6.2.7 stphanet."

Information