PRIMECLUSTER GLS for Windows User's Guide 4.3

2.2.3 Restore Function

When the GLS monitor function detects a successful restore after a failure, the restore function automatically re-establishes the connection.

Restoring

When a transmission path in which a failure occurred is restored, GLS automatically performs the following tasks:

When an Operational Physical Adapter Exists

When an operational physical adapter exists, the physical adapter on the restored transmission path becomes available as the standby adapter.

Figure 2.5 Restoring (When an Operational Physical Adapter Exists)

When No Operational Physical Adapter Exists

When no operational physical adapter exists, the physical adapter on the restored transmission path is connected as the operational adapter and communication is resumed.

Figure 2.6 Restoring (When No Operational Physical Adapter Exists)