Event traps are messages reported from a device. If you have any questions about the message contents, refer to the instruction manual for hardware to take corrective actions.
Failure event | Level | Event display |
---|---|---|
Library hardware error | Error | Library system failed. Use the Remote Panel to check the error contents(FSC=xx, Sensekey=xx). |
Barcode reader error | Warning | Barcode reader failed. |
CM reader error | Warning | CM reader failed. |
CAS error | Warning | CAS unit#number failed. |
Cell error | Warning | Cell unit failed (Barcode Label:xxxxx). |
CIC sensor error | Warning | CIC sensor failed. |
Battery alarm | Warning | Battery unit failed. |
Shelf FAN0 alarm | Warning | Shelf FAN#0 failed. |
Shelf FAN1 alarm | Warning | Shelf FAN#1 failed. |
Library FAN0 alarm | Warning | Library FAN#0 failed. |
Library FAN1 alarm | Warning | Library FAN#1 failed. |
Library FAN2 alarm | Warning | Library FAN#2 failed. |
CAS unlock error | Warning | An Unlock error occurred in CAS unit#number. |
FC/SCSI error | Warning | Adapter#number failed. |
Boot up alarm | Warning | Bootup alarm occurred. |
MAC address alarm | Warning | EEPROM failed. |
Shelf PSU alarm | Warning | Shelf PSU#number unit failed. |
Shelf PSU not installed | Warning | Shelf PSU#number is not installed. |
Thermal alarm | Warning | Tape library temperature increased (temperature degree C), leading to an alarm. |
Thermal error | Error | Tape library temperature increased abnormally (temperature degree C), leading to a library system fail. |
Humidity alarm | Warning | Tape library humidity (humidity %) is abnormal. |
Front door open (during operation) | Warning | Front door of the library system was opened. |
Nearing no cleaning tape | Warning | The installed cleaning cartridges will reach a limit soon. |
Cleaning tape limit | Warning | Maximum number of uses of cleaning cell#number (Barcode Label: xxxxx) was reached. |
No cleaning tape | Warning | Cleaning cartridge is not available. |
ROBOT Serdes alarm | Warning | Robot serdes failed. |
Power control card alarm | Warning | Power control card failed. |
Operator Panel P-Off alarm | Warning | Power-off occurred in operation panel. |
Nearing Media Life | Warning | Media soon will be end of life. (Barcode Label:xxxxx) |
Reach Media Life | Warning | Media reached at the end of life. (Barcode Label:xxxxx) |
Reach ROBOT life | Warning | Robot reached at the end of life. |
Magazine set sensor error | Warning | Magazine set sensor in CAS#number failed. |
No magazine | Warning | Magazine in CAS#number is not installed. |
Trash cell full | Warning | There is a media in the Trash cell. (Barcode label:xxxxx) |
Media error (CM) | Warning | An error occurred in media error(CM fail).(Barcode Label:xxxxx) |
Drive hardware error | Error | An error occurred in drive#number. Use the Remote Panel to check the error contents (FSC=xx, Sensekey=xx). |
Media error | Warning | An Error occurred in media error (Barcode Label:xxxxx). |
Drive FAN alarm | Warning | A FAN alarm occurred in drive#number. |
Drive cleaning request | Warning | Drive#number needs cleaning. Perform cleaning. |
Reach Drive Life | Warning | Drive#number reached at the end of life. |
Drive PSU power off alarm | Warning | Power-off occurred in drive PSU#number unit. |
Drive PSU alarm | Warning | Drive PSU#number unit failed. |
Drive LCT/DC IF alarm | Warning | Interface between LCT and DC failed. |
Grease is necessary | Warning | Need Greasing. |