Event traps are messages reported from a device. If you have any questions about the message contents, refer to the instruction manual for hardware to take corrective actions.
Failure event | Level | Event display |
---|---|---|
Library hardware error | Error | Library system failed. Use the Remote Panel to check the error contents (FSC=xxxx, Sensekey=xxxx). |
Barcode reader error | Warning | Barcode reader in robot#number failed. |
CM error | Warning | An error occurred in media error(CM fail).(Barcode Label=xxxx) |
CAS cell error | Warning | CAS unit number error occurred. |
Cell error | Warning | Cell unit failed.(Barcode Label=xxxxx) |
CIC sensor error | Warning | CIC sensor in robot #number failed. |
Battery alarm | Warning | Battery unit in LCT#number failed. |
Shelf 0 fan alarm | Warning | Shelf FAN in LCT#0 failed. |
Shelf 1 fan alarm | Warning | Shelf FAN in LCT#1 failed. |
CAS open error | Warning | An open error occurred in CAS unit number |
FC/SCSI adapter card error | Warning | Adapter#number failed. |
Firmware BOOTUP alarm | Warning | The LCT#number bootup alarm occurred. |
EEPROM error | Warning | EEPROM failed. |
ROBOT PSU alarm | Warning | PSU unit in robot robot#number failed. |
ROBOT PSU power off alarm | Warning | Power-off occurred in PSU unit in robot#number. |
ROBOT PSU FAN alarm | Warning | PSU unit FAN in robot#number failed. |
Temperature alarm | Warning | The temperature in the library is abnormal.(temperature degree C). |
Temperature abnormality error | Error | Tape library temperature increased abnormally (temperature degrees C), leading to a library system fail. |
Vibration alarm | Warning | Library system detected an abnormal vibration. |
Humidity alarm | Warning | Tape library humidity (humidity %) is abnormal. |
LCT failover alarm | Warning | Failover occurred in LCT#number. |
LCT cutoff alarm | Warning | Cutoff occurred in LCT#number. |
ROBOT Down alarm | Warning | Robot#number failed. |
Front door open (during operation) | Warning | Front door of the library system was opened. |
Nearing no cleaning tape | Warning | The installed cleaning cartridges will reach a limit soon. |
Expired deadline for cleaning | Warning | Maximum number of uses of cleaning cell#number (barcode label: xxxx) was reached. |
Cleaning cartridge none | Warning | Cleaning cartridge is not available. |
ROBOT Serdes alarm | Warning | Serdes in robot#number failed. |
Power control card alarm | Warning | Power control card in LCT#number failed. |
LCD power off alarm | Warning | Power-off occurred in operation panel. |
Drive hardware error | Error | An error occurred in drive#number. Use the remote panel to check the error contents (FSC=xxxx, Sensekey=xxxxxx). |
Media error | Warning | An Error occurred in media error (barcode label:xxxxxx). |
Fan alarm | Warning | A FAN alarm occurred in drive #number. |
Cleaning request | Warning | Drive#number needs cleaning. Perform cleaning. |
Cluster PSU0 power off alarm | Warning | Power-off occurred in PSU0 in drive cluster#number. |
Cluster PSU1 power off alarm | Warning | Power-off occurred in PSU1 in drive cluster#number. |
Cluster PSU0 alarm | Warning | PSU0 in drive cluster#number failed. |
Cluster PSU1 alarm | Warning | PSU1 in drive cluster#number failed. |
LCT/DCT0 IF failure | Warning | Interface between LCT#number and DCI#0 (drive cluster#number) failed. |
LCT/DCT1 IF failure | Warning | Interface between LCT#number and DCI#1 (drive cluster#number) failed. |
DCT0 failure | Warning | DCI#number in drive cluster#number failed. |
DCT1 failure | Warning | DCI#number in drive cluster#number failed. |
Nearing Media Life | Warning | Media soon will be end of life (Barcode Label:xxxxx). |
Reach Media Life | Warning | Media reached at the end of life (Barcode Label:xxxxx). |
Reach ROBOT life | Warning | Robot#number reached at the end of life. |
Reach Drive Life | Warning | Drive#number reached at the end of life. |