Top
ETERNUS SF Storage Cruiser 14.1 Installation Guide

3.3.2 Incompatibility in Version 13.2

Change the Argument-1 value to be handed over to the event linked functionality
Incompatibility details

Version

Details

13.1 or before

SN200 Product name in an error message to be handed over to argument-1 will be handed over as "SilkWorm xxxx".

13.2

SN200 product name in an error message to be handed over to argument-1 will be handed over as "xxxx."

Example

Case of version 13.1 or before:

"AP:SSC: INFO: swsag4203:FC Port No.0 Online in M540(SilkWorm 48000[192.168.0.1])"

Case of version 13.2:

"AP:SSC: INFO: swsag4203:FC Port No.0 Online in M540(48000[192.168.0.1])"

Change the install directory and command name of the restart and stop commands of the administrative server daemon
Incompatibility object

Solaris OS Manager

Incompatibility details

Version

Details

13.1 or before

/opt/FJSVrcxmr/sbin/rcxmgrctl

13.2

/opt/FJSVssmgr/sbin/managerctl

See

For details, refer to "12.1.2.2 Starting and stopping the daemons of the administrative server at specific times" in the ETERNUS SF Storage Cruiser User's Guide.

Change the install directory and command name of the command for investigation data collection on the administrative server
Incompatibility object

Solaris OS Manager

Incompatibility details

Version

Details

13.1 or before

/opt/FJSVrcxmr/sbin/rcxmgrsnap

13.2

/opt/FJSVssmgr/sbin/managersnap

See

For details, refer to "Appendix D Troubleshooting" in the ETERNUS SF Storage Cruiser User's Guide.

Change the cmdline resource path for cluster environment
Incompatibility object

Solaris OS Manager

Incompatibility details

Version

Details

Start script

13.1 or before

/opt/FJSVrcxmr/cluster/cmd/rcxclstartcmd

13.2

/opt/FJSVssmgr/cluster/cmd/rcxclstartcmd

Stop script

13.1 or before

/opt/FJSVrcxmr/cluster/cmd/rcxclstopcmd

13.2

/opt/FJSVssmgr/cluster/cmd/rcxclstopcmd

Check script

13.1 or before

/opt/FJSVrcxmr/cluster/cmd/rcxclcheckcmd

13.2

/opt/FJSVssmgr/cluster/cmd/rcxclcheckcmd

See