Top
ETERNUS SFAdvancedCopy Manager 14.0 Operator's Guide forCopy Control Module

B.2.1 Detailed Messages

no such session.

Description

There is no session for the specified copy pair.

System response

Interrupts the processing.

System administrator response

Operations cannot be executed on copy pairs for which there is no copy session.

Check the session status using either A.5.2 acopc query (Status display command for snapshot type high-speed copying) or A.6.2 acec query (Status display command for synchronous high-speed copying).

invalid logical volume name.

Description

Either the access path specified at ETERNUS storage system registration time or the device name specified using a command is invalid.

System response

Interrupts the processing.

System administrator response

Check that the specified device name is correct.

Or, check the drive letter or device name specified in the access path.

STXS1027

The specified parameter is invalid. [parameter name=[PARAMETER NAME], parameter value=[PARAMETER VALUE]]

Description

An incorrect affinity group number has been specified.

Parameters

PARAMETER NAME: Parameter name

PARAMETER VALUE: Parameter value

System response

Interrupts the processing.

System administrator response

Use A.3.3 acinq ag (Command for displaying a list of affinity groups) to check the specified affinity group number.

STXS2001

The specified user name and password have not been registered in the device. [user=[USER]]

Description

The user name and password have not been registered on the ETERNUS storage system.

Parameters

USER: User name

System response

Interrupts the processing.

System administrator response

Check whether the user name and password are correct.

STXS2002

The specified user does not have privileges greater than that of an administrator. [user=[USER]]

Description

The user does not have Administrator privileges.

Parameters

USER: User name

System response

Interrupts the processing.

System administrator response

Use ETERNUSmgr to check the user privileges.

STXS2008

The registered user and password are not registered in the current device. [IP address=[IP ADDRESS], user=[USER]]

Description

The user name and password have not been registered on the ETERNUS storage system.

Parameters

IP ADDRESS: IP address

USER: User name

System response

Interrupts the processing.

System administrator response

The ETERNUSmgr user account has either been changed or deleted.

Change the registration information for the ETERNUS storage system by referring to "3.4 Changing the Configuration ".

STXS2009

The operation cannot be performed with the user privileges when registering the device. [IP address=[IP ADDRESS], user=[USER]]

Description

The user does not have Administrator privileges.

Parameters

IP ADDRESS: IP address

USER: User name

System response

Interrupts the processing.

System administrator response

The user account privileges for ETERNUSmgr have been changed.

Use ETERNUSmgr to check the user privileges.

STXS4002

The device is not supported. [IP address=[IP ADDRESS], model=[MODEL], type=[TYPE]]

Description

The specified ETERNUS storage system is not supported.

Parameters

IP ADDRESS: IP address

MODEL: ETERNUS storage system model

TYPE: ETERNUS storage system type

System response

Interrupts the processing.

System administrator response

Check that the ETERNUS storage system meets the "1.4.1 Hardware requirements".

STXS4046

The specified affinity group has not been registered. [affinity group number=[AFFINITY GROUP NUMBER]]

Description

The specified affinity group has not been registered.

Parameters

AFFINITY GROUP NUMBER: Affinity group number

System response

Interrupts the processing.

System administrator response

Use A.3.3 acinq ag (Command for displaying a list of affinity groups) to check the specified affinity group number.

STXS4047

The specified affinity group has been concatenated. [affinity group number=[AFFINITY GROUP NUMBER]]

Description

A concatenated affinity group has been specified.

Parameters

AFFINITY GROUP NUMBER: Affinity group number

System response

Interrupts the processing.

System administrator response

Concatenated affinity groups cannot be specified.

STXS7004

Failed to communicate with the device. [IP address=[IP ADDRESS]]

Description

Communications with the ETERNUS storage system have failed.

Parameters

IP ADDRESS: IP address

System response

Interrupts the processing.

System administrator response

It is not possible to communicate with the ETERNUS storage system.

Refer to "Port number settings" to check the status of the network, and then execute the command again.