Top
ETERNUS SF Storage Cruiser 14.0 User's Guide

4.3.2 Disk array ETERNUS SX300, ETERNUS SX300S

This software supports fault management (SNMP trap monitoring only) of the disk array ETERNUS SX300, ETERNUS SX300S. Follow the procedure below to register the disk array as a manually embedded device:

  1. Registering the SANtricity installation server

    SNMP traps of ETERNUS SX300 and ETERNUS SX300S are sent from the server on which the device management software SANtricity is installed.
    The SANtricity installation server must be registered with this software to perform SNMP trap monitoring.
    Register the SANtricity installation server with this software by using either of the following methods:

    • Install ETERNUS SF Storage Cruiser Agent on the SANtricity installation server, and then register the server as a managed server node.

    • Use the manual embedding function to register the SANtricity installation server as a manually embedded host
      (Be sure to enter the IP address of the server node).

  2. Registering the ETERNUS SX300, ETERNUS SX300S device

    Use the manual embedding function to register the ETERNUS SX300, ETERNUS SX300S device with this software.
    The following information must be set for the registration:

    • Specify the device name marked in SANtricity in "Device name". (E.g. SX3RF2B-000001)
      Note that monitoring cannot be performed correctly if the device name is incorrect.

    • Enter the IP address of the SANtricity installation server in "IP address".

  3. SNMP trap setting

    Set the trap transmission destination on the SANtricity installation server so that SNMP traps of ETERNUS SX300, ETERNUS SX300S will be sent to the operation management server.
    If the operation management server is defined as a cluster, the logical IP address of the cluster needs to be set.