Event traps are messages reported from a device. If you have any questions about the message contents, refer to the instruction manual for hardware to take corrective actions.
Depending on the event level, the corresponding icon may turn red (Error) or yellow (Warning).
(In case of the level "Information," the icon color is not changed.)
Failure event | Level | Event display |
---|---|---|
Library hardware error | Error | Library system failed. Use the Remote Panel to check the error contents(FSC=xx, Sensekey=xx). |
Barcode reader error | Warning | Barcode reader failed. |
CM reader error | Warning | CM reader failed. |
CAS error | Warning | CAS unit#number failed. |
Cell error | Warning | Cell unit failed (Barcode Label:xxxxx). |
CIC sensor error | Warning | CIC sensor failed. |
Battery alarm | Warning | Battery unit failed. |
Shelf FAN0 alarm | Warning | Shelf FAN#0 failed. |
Shelf FAN1 alarm | Warning | Shelf FAN#1 failed. |
Library FAN0 alarm | Warning | Library FAN#0 failed. |
Library FAN1 alarm | Warning | Library FAN#1 failed. |
Library FAN2 alarm | Warning | Library FAN#2 failed. |
CAS unlock error | Warning | An Unlock error occurred in CAS unit#number. |
FC/SCSI error | Warning | Adapter#number failed. |
Boot up alarm | Warning | Bootup alarm occurred. |
MAC address alarm | Warning | EEPROM failed. |
Shelf PSU alarm | Warning | Shelf PSU#number unit failed. |
Shelf PSU not installed | Warning | Shelf PSU#number is not installed. |
Thermal alarm | Warning | Tape library temperature increased (temperature degree C), leading to an alarm. |
Thermal error | Error | Tape library temperature increased abnormally (temperature degree C), leading to a library system fail. |
Humidity alarm | Warning | Tape library humidity (humidity %) is abnormal. |
Front door open (during operation) | Warning | Front door of the library system was opened. |
Nearing no cleaning tape | Warning | The installed cleaning cartridges will reach a limit soon. |
Cleaning tape limit | Warning | Maximum number of uses of cleaning cell#number (Barcode Label: xxxxx) was reached. |
No cleaning tape | Warning | Cleaning cartridge is not available. |
ROBOT Serdes alarm | Warning | Robot serdes failed. |
Power control card alarm | Warning | Power control card failed. |
Operator Panel P-Off alarm | Warning | Power-off occurred in operation panel. |
Nearing Media Life | Warning | Media soon will be end of life. (Barcode Label:xxxxx) |
Reach Media Life | Warning | Media reached at the end of life. (Barcode Label:xxxxx) |
Reach ROBOT life | Warning | Robot reached at the end of life. |
Magazine set sensor error | Warning | Magazine set sensor in CAS#number failed. |
No magazine | Warning | Magazine in CAS#number is not installed. |
Trash cell full | Warning | There is a media in the Trash cell. (Barcode label:xxxxx) |
Media error (CM) | Warning | An error occurred in media error(CM fail).(Barcode Label:xxxxx) |
Drive hardware error | Error | An error occurred in drive#number. Use the Remote Panel to check the error contents (FSC=xx, Sensekey=xx). |
Media error | Warning | An Error occurred in media error (Barcode Label:xxxxx). |
Drive FAN alarm | Warning | A FAN alarm occurred in drive#number. |
Drive cleaning request | Warning | Drive#number needs cleaning. Perform cleaning. |
Reach Drive Life | Warning | Drive#number reached at the end of life. |
Drive PSU power off alarm | Warning | Power-off occurred in drive PSU#number unit. |
Drive PSU alarm | Warning | Drive PSU#number unit failed. |
Drive LCT/DC IF alarm | Warning | Interface between LCT and DC failed. |
Grease is necessary | Warning | Need Greasing. |