PRIMEQUEST System Disk Mirror for Windows User's Guide V1.0
Contents PreviousNext

Appendix C Notes

C.3 Troubleshooting

 

Boot disk mirroring setup or operation fails in the environment connecting ETERNUS.

[Explanation]

If the following conditions are all satisfied, an error may occur in the mirroring setup or operation. Additionally, under these circumstances, the mirror destination disk may become INVALID after synchronization copying or resynchronization copying is completed.

  1. The ETERNUS multipath driver is not in use.

  2. The ETERNUS disk array unit is connected or disconnected during system operation or ETERNUS is not recognized by the system due to its malfunction.

  3. The system has not been shut down after 2.

If the conditions 1. to 3. are satisfied, the OS bootcfg command will not function normally, and thus, EFI boot entry addition and deletion will fail, which causes this error.

The above event is assumed to be the cause if:

[Resolution]

Perform the following procedures for restoration.

  1. Shut down the system.

  2. Restore the failed component if an ETERNUS disk or cable is faulty.

  3. Reboot the system.

  4. Take action responding to the message (42008, 42011, 44002, or 44006) for the service (F6GASRV) output in the system log in the event log.


For the resolutions relevant to the service messages, see "Service Messages."



Contents PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2008