ETERNUS SF Storage Cruiser Install Guide 13.2 - Solaris (TM) Operating System / Linux / Microsoft(R) Windows(R) - |
Contents
![]() ![]() |
To manage HBAs installed on Solaris OS server nodes, it is necessary to install and configure the following HBA vender's SNIA HBA API library.
By installing PW008FC2A, PW008FC2-G, PW008FC3, GP7B8FC1A, GP7B8FC1-G, or GP7B8FC1 drivers (FUJITSU PCI Fibre Channel 2.2.1 or 3.0), the SNIA HBA API library is installed.
Additionally, for FUJITSU PCI Fibre Channel 2.2.1, it is necessary to apply required patches (912069-17 or later). FUJITSU PCI Fibre Channel 2.2 is not supported.
Please refer to the manual of the driver and install HBAnyware (SNIA HBA API).
After installing the SE0X7F11F or SE0X7F12F driver (FUJITSU PCI Fibre Channel 4.0 or later), the SNIA HBA API library must be changed using the following procedure:
Change the link between /usr/lib/libfchba.so and /opt/FJSVpfca/sbin/libfchba.so to /opt/FJSVpfca/sbin/libfchba1.so.
# rm /usr/lib/libfchba.so
# ln -s /opt/FJSVpfca/lib/libfchba1.so /usr/lib/libfchba.so
Reboot.
# /usr/sbin/shutdown -y -i6 -g0
Setting of the SNIA HBA API library is not required as it is included in the driver handled by the operating system.
The SNIA HBA API library does not require settings, as it is already included in the driver bundled with the operating system.
To manage HBA installed on a Linux/VMware server node, install the following HBA vendor's HBA API library.
Check whether the following two conditions are met to determine the installation status. If both the conditions are met, the HBA API library has been installed.
All the following files exist:
/usr/lib/libHBAAPI.so
/usr/lib/libemulexhbaapi.so
/etc/hba.conf
An integer larger than or equal to "1" is displayed as a result of the following command execution.
# egrep -c [^[:blank:]]+[[:blank:]]+/usr/lib/libemulexhbaapi.so /etc/hba.conf <RETURN> |
For driver version V1.23a-0 or V4.20q-1
Please install the SNIA HBA API common library (for Common HBA API Version 2.18) using the following procedure.
Back up the /usr/lib/libHBAAPI.so file if it exists.
For /opt/FJSVssagt/lib/libHBAAPI.so, create a copy in /usr/lib/, or create a symbolic link with the following command.
# ln -s /opt/FJSVssage/lib/libHBAAPI.so /usr/lib/libHBAAPI.so <RETURN> |
For "libemulexhbaapi.so" (SNIA HBA API vendor specific library), please obtain it from Fujitsu technical staff, then install.
For driver versions other than V1.23a-0 or v4.20g-1
For the SNIA HBA API library for Linux, please obtain it from Fujitsu technical staff, then install.
For VMware:
Download the SNIA HBA API library appropriate for VMware version and driver version from the website of Emulex. Then, install according to the document attached to the SNIA HBA API library.
Check whether the following two conditions are met to determine the install status. If both the conditions are met, the HBA API library has been installed.
All the following files exist:
/usr/lib/libHBAAPI.so
/usr/lib/libqlsdm.so (* For VMware, /usr/lib/libqlsdm-ia32.so will do.)
/etc/hba.conf
An integer larger than or equal to "1" is displayed as a result of the following command execution.
# egrep -c [^[:blank:]]+[[:blank:]]+/usr/lib/libqlsdm.so /etc/hba.conf <RETURN> |
However, for VMware, if it falls under the *-marked point in the preceding item, executing the following command will result in display of an integer value "1" or more.
# egrep -c [^[:blank:]]+[[:blank:]]+/usr/lib/libqlsdm-ia32.so /etc/hba.conf <RETURN> |
For Linux:
Please install the SNIA HBA API common library (for Common HBA API Version 2.18) using the following procedure.
Back up the /usr/lib/libHBAAPI.so file if it exists.
For /opt/FJSVssagt/lib/libHBAAPI.so, create a copy in /usr/lib/, or create a symbolic link with the following command.
# ln -s /opt/FJSVssage/lib/libHBAAPI.so /usr/lib/libHBAAPI.so <RETURN> |
For "libqlsdm.so" (SNIA HBA API vendor specific library), please obtain it from Fujitsu technical staff, then install.
For VMware:
Download the QLA2342 SNIA HBA API library appropriate for VMware version and driver version from the website of QLogic Corporation. Then, install according to the document attached to the SNIA HBA API library.
The MC-08FC11 install status checking method is similar to the methods for PG-FC105, PG-FC106, PG-FC107 and PG-FC201. For details, please refer to "B.2.1.1 HBA API library installation check".
Please install HBAnyware (SNIA HBA API) according to the HBA card's instruction manual or the driver's manual.
To manage the HBA installed in a Windows server node, please install the following HBA vendor's SNIA HBA API library.
For PG-FC105/PG-FC106/PG-FC107/PG-FC201/PG-FC202/PG-FCD201,and Emulex's LP9000/LP9002L/LP9802/LP1050/LP1050Ex
Please install HBAnyware (SNIA HBA API) according to the HBA card's instruction manual or the driver's manual.
When using the driver version v5-2.13a4 (Windows2000) with PG-FC105, this configuration is not necessary.
To use PG-FC202 or PG-FCD201, change the agent-installation-directory\Agent\bin\HBAAPI.dll to another name (for example, HBAAPI.dll.bak).
If the agent-installation-directory\Agent\bin\HBAAPI.dll does not exist, file name change is not necessary.
For PG-FCD101/PG-FCD102 and Qlogic's QLA2340
Please install the SNIA HBA API common library (for Common HBA API Version 2.18).
Copy agent-installation-directory \Agent\lib\HBAAPI.dll to agent-installation-directory \Agent\bin\HBAAPI.dll.
When the same files already exist in the copy destination, copying is not necessary.
For MC-08FC11/MC-08FC31/MC-08FC41/MC-08FC51/MC-08FC61/MC-08FC71
Please install HBAnyware (SNIA HBA API) according to the HBA card's instruction manual or the driver's manual.