To enable the operator intervention function, you have to set the AppWatch parameter to ON with clsetparam. With the default settings made when the cluster was installed, the operator intervention function is disabled. For details, see "Setting Up Fault Resource Identification and Operator Intervention Request."
The operator intervention function is always enabled.
The operator intervention function is enabled only when the AppWatch parameter is set to ON with clsetparam. The default value of AppWatch set when the cluster was installed is set to OFF, and the operator intervention function will not work with this default value.
After you have changed the AppWatch parameter with clsetparam, you have to reboot all the nodes to validate the setting.