PRIMECLUSTER Global File Services Configuration and Administration Guide 4.2 (Solaris(TM) Operating Environment)
Contents Index PreviousNext

Appendix A Kernel Messages> A.1 Diagnostics

A.1.59 WARNING: sfxfs:0076: mount_point: primary partition configuration read failed, but secondary read. dev = dev_num block = block_num size = size

[Explanation]

The primary set of partition configuration information for the indicated device could not be read but the secondary set of partition configuration information was read successfully, and the system therefore continues processing.

[Action]

File system manipulation can be continued. However, since a block error occurred, promptly act according to the Appendix C, "Corrective Measures against I/O Errors in the GFS Local File System."


Contents Index PreviousNext