Machine Administration Guide 2.6
Contents Index PreviousNext

Appendix B Disk Drive Replacement> B.6 Messages

B.6.3 Messages output to /var/adm/messages

Message

ERROR: <disk>: <device>: ready for swapping due to I/O error, class=<class>

Explanation

Because an I/O error occurred on the disk <disk> in class <class>, the physical disk <device> has been logically unmounted from GDS administration so that it can be replaced.

Appropriate action

Replace the relevant disk using the disk drive replacement menu.

However, if this message is followed by error message "ERROR: <device>: setup for hot-swap failed" output to the console, take action according to the response provided for the error message.

 

Message

ERROR: <device>: setup for hot-swap failed

Explanation

The physical disk <device> has been logically unmounted from GDS administration so that it can be replaced, but it could not be unmounted electrically.

Appropriate action

Check for errors in the route to the disk (related PCI adapters, cables, extended file units, etc.)

After error recovery, use the hot swap menu to perform swap processing.

 

Message

chgdisk : Power supply of disk is cut off. (<device>)

Explanation

The disk drive <device> has been electrically disconnected successfully.

Appropriate action

Perform swapping using the disk drive replacement menu.

If this message is displayed during execution of the replacement menu item, ignore the message.


Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2001-2005
All Rights Reserved, Copyright (C) PFU LIMITED 2001-2005