Machine Administration Guide 2.6 |
Contents
Index
![]() ![]() |
Appendix B Disk Drive Replacement | > B.6 Messages |
Message |
ERROR: <disk>: <device>: ready for swapping due to I/O error, class=<class> |
Explanation |
Because an I/O error occurred on the disk <disk> in class <class>, the physical disk <device> has been logically unmounted from GDS administration so that it can be replaced. |
Appropriate action |
Replace the relevant disk using the disk drive replacement menu. However, if this message is followed by error message "ERROR: <device>: setup for hot-swap failed" output to the console, take action according to the response provided for the error message. |
Message |
ERROR: <device>: setup for hot-swap failed |
Explanation |
The physical disk <device> has been logically unmounted from GDS administration so that it can be replaced, but it could not be unmounted electrically. |
Appropriate action |
Check for errors in the route to the disk (related PCI adapters, cables, extended file units, etc.) After error recovery, use the hot swap menu to perform swap processing. |
Message |
chgdisk : Power supply of disk is cut off. (<device>) |
Explanation |
The disk drive <device> has been electrically disconnected successfully. |
Appropriate action |
Perform swapping using the disk drive replacement menu. If this message is displayed during execution of the replacement menu item, ignore the message. |
Contents
Index
![]() ![]() |