Machine Administration Guide 2.6
Contents Index PreviousNext

Appendix B Disk Drive Replacement> B.6 Messages

B.6.2 Messages displayed when an error occurs during replacement

Error messages may be displayed on the result display screen at the time of completion of mount processing after hot or cold swap. The following error messages are displayed for individual disks on which an error occurred.

Message

Exclude failed.

Explanation

Electrical disconnection processing of a disk failed.

Appropriate action

Check for proper configuration/status of PCI adapter, file unit (file bay) and cable between them.

 

Message

Connection failed during spinup.

Explanation

Electrical mount processing of a disk failed.

Appropriate action

Check for proper configuration/status of PCI adapter, file unit (file bay) and cable between them.

 

Message

Resynchronization copying was failed, or command to display progress was failed.

Explanation

Resynchronization copying failed because of an error after replacement.

Alternatively, command execution failed because of a software error.

Appropriate action

This failure could be caused not only by hardware, but also by software related issues. Check disk status on the SynfinityDisk/GDS menu. When you can confirm by the menu that all disks are properly configured and working, you can finish your maintenance work. When the menu shows only newly replaced disk is excluded by GDS, confirm whether the source disk or destination disk is properly installed. In addition to this, check a route to the disks, such as a cable or PCI adapter. You should then reattempt this replacement procedure. If you see any other problem, please consult a manual of SynfinityDisk/GDS.

 

Message

The disks cannot be included in GDS because a disk is in the process of resynchronization copying.

(Class:<class>, Disk:<disk>)

Explanation

The specified disk cannot be mounted in GDS because the group to which the disk belongs contains another disk that is subject to resynchronization copying.

Appropriate action

Wait until resynchronization copying is complete, then use the sdxswap command or GUI to include the disk.

After the resynchronization copying is complete, perform the same procedures again.

 

Message

The disk cannot be included in GDS because it cannot be recognized correctly.

(Class:<class>, Disk:<disk>)

Explanation

The specified device cannot be recognized as a disk drive.

Appropriate action

Check whether power is turned on normally, or check the format of the disk drive.

After recovery, use the sdxswap command or the GUI to mount the disk.

[Check the connection and formatting status of the disk.]

 

Message

The disk cannot be included in GDS because the disk size is insufficient.

(Class:<class>, Disk:<disk>)

Explanation

The specified disk cannot be mounted in GDS because the disk size is too small.

Appropriate action

Use a disk with a size equal to or greater than the original disk used before replacement.

After replacement, use the sdxswap command or GUI to mount the disk.

[Mount a disk of the same size as or of a size larger than that of the original disk, and perform the procedure again.]

 

Message

The disk cannot be included in GDS.

(Class:<class>, Disk:<disk>)

Explanation

The sdxswap -I command terminated abnormally. Alternatively, the specified device could not be found.

Appropriate action

Check the GDS configuration and status based on the console messages, GDS log, and output of the sdxinfo command.

After recovery of GDS, use the sdxswap command or the GUI to perform mount processing.

[Check the GDS configuration and status.]

 

Message

The disk cannot be excluded from GDS.

(Class:<class>, Disk:<disk>)

Explanation

The sdxswap -O command terminated abnormally. Alternatively, the specified device could not be found.

Appropriate action

Check the GDS configuration and status based on the console messages, GDS log, and output of the sdxinfo command.

After recovery of GDS, retry the operation.

[Check the GDS configuration and status.]


Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2001-2005