Machine Administration Guide 2.6 |
Contents
Index
![]() ![]() |
Chapter 4 Command Reference |
The init and set subcommands are not supported by PRIMEPOWER250/450/650/850.
Displays the RCI status of the main unit and the addresses and the statuses of the devices connected to the RCI.
Active : RCI is active.
Mainte : RCI is in maintenance mode.
Configuring : The RCI network is being constructed.
ConfigError(reason) : RCI network construction error.
In (reason), one of the following reasons is displayed.
Reason |
Reason for the status |
"Self Host Address Conflict" |
Local address duplication error |
"Host Address Contradict" |
Host number or host address inconsistency |
"RCI Address Contradict" |
RCI address inconsistency |
"Can't assign new Address" |
New registration unacceptable |
"Error in Configuring" |
Error in incorporation |
"Self configuration RCI Address Conflict" |
Locally constructed RCI address duplication error |
"RCI Hardware Error" |
RCI hardware error |
The following information is displayed for each RCI-connected unit.
Address: RCI Address
Use this information to specify a device for hot swapping of fans or power supply units.
Pwr: Power supply status
Status |
Definition |
ON |
Power-on status |
OFF |
Power-off state |
Alm: Alarm out status
Status |
Definition |
ALM |
Alarm out status |
- |
No alarm |
I/F: Interface status
Status |
Definition |
ACT |
Active status |
INACT |
Inactive status |
sys-phase: OS status
Status |
Definition |
power-off |
Power-off state |
panic |
Panic status |
shdwn-start |
Shutting down |
shdwn-cmplt |
Shutdown completed |
dump-cmplt |
Dump completed |
OBP/POST |
Initial diagnosis in progress |
booting |
Booting |
running |
Running |
Ctgry: Category
Category |
Definition |
host |
Main unit |
rcic |
External power supply unit |
disk |
Disk unit |
lnsw |
Line switch |
other |
Other device |
dev-cls: device class
Four digits in hexadecimal format. |
sub-cls: subclass
Two digits in hexadecimal format. |
tm-out: Monitoring time of no-communication-timeouts
The monitoring time of no-communication-timeouts of monitoring of the RCI unit is displayed. For devices not supported, "-" is displayed. |
# /usr/sbin/FJSVmadm/setrci stat
HOST
address 000101ff
Active
LIST
address pwr alm I/F sys-phase ctgry dev-cls sub-cls tm-out
000101ff ON - ACT running host 0001 04 -
000102ff ON - ACT running host 0001 04 -
000103ff ON - ACT running host 0001 04 -
000104ff ON - ACT running host 0001 04 -
000105ff ON - ACT running host 0001 04 -
000106ff ON - ACT running host 0001 04 -
003001ff ON - ACT - rcic 0200 02 40
003002ff ON - ACT - rcic 0200 02 40
003003ff OFF ALM ACT - disk 0400 02 40
003004ff ON - ACT - disk 0400 05 180
002009ff ON - ACT - lnsw 0800 01 40
Sets the RCI address to the default value.
Sets the RCI address of the host.
Displays the settings of the RCI maintenance mode.
In maintenance mode, the system performs general monitoring processing but it does not report errors. This mode is used for maintenance of RCI-connected units.
You can set the maintenance mode using the mode switch located on the front panel of the main unit.
This command displays the mode of the current RCI network.
# /usr/sbin/FJSVmadm/setrci mainte
RCI Maintenance Mode: enable
Instructs initial incorporation of an RCI device.
For reconfiguration of an RCI, issue the instruction for its incorporation.
Instructs incorporation of an RCI device.
For reconfiguration of an RCI after addition or reduction of RCI devices, issue the instruction for its incorporation.