Machine Administration Guide 2.6
Contents Index PreviousNext

Chapter 4 Command Reference

4.36 setfanlife (1M)

Name
setfanlife - Fan life monitoring display/setting command
Format
/usr/sbin/FJSVmadm/setfanlife fan_name [hours | -i | -d]
Function
Sets fan life monitoring and displays the power-on time.
Option
The options are:
fan_name
Specify the target fan name.
Specify a fan name in the following form:
Fan for the base cabinet: FAN#n
FEP of the base cabinet: FEPFAN#n
Fan for an expansion cabinet: rci-address-FAN#n
FEP for an expansion cabinet: rci-address-FEPFAN#n
n
is an identification number.
If you specify only a fan name, the system displays the power-on time of the specified fan.
hours
Specify the power-on time of the specified fan.
If you replace a fan with a new fan, specify 0.
If you install ESF again, the power-on time of a fan becomes 0.
Before you install the main unit again, set the power-on time.
-i
When you replace a fan, specify the fan name and initialize the monitoring information using this parameter.
-d
If you remove a fan, specify the fan name and delete the life monitoring information using this parameter.
Example of use
The following shows an example of setting the power-on time of FAN#0.
# /usr/sbin/FJSVmadm/setfanlife FAN#0 0

The following shows an example of the power-on time of FAN#2 installed on a cabinet whose RCI address is 003001ff.

# /usr/sbin/FJSVmadm/setfanlife 003001ff-FAN#2
003001ff-FAN#2  100  hours
End status
The end status can be:
0: Normal end
Other than 0: Error

Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2001-2005
All Rights Reserved, Copyright (C) PFU LIMITED 2001-2005