This section describes how to perform Console Administration.
Lists the Console Administration information.
console |
: |
Input and output destinations of the standard console of the main unit |
RW-port |
: |
Current status of port 23 (standard console) |
RO-port |
: |
Current status of port 8011 (read-only console) |
SCF-port |
: |
Current status of port 8010 (remote XSCF connection and XSCF shell) |
timeout |
: |
<enable or disable> Status of the automatic no-communication disconnection function of an XSCF shell |
time |
: |
<time> Status of the automatic no-communication disconnection function of an XSCF shell |
However, time is displayed only when timeout is set to "enable." |
Change the setting for the standard console.
Switches the input-output channels of the standard console to the ordinary serial port.
Switches the input-output channels of the standard console to the XSCF LAN.
XSCF controls the standard console (/dev/console) of the main unit using a network via TCP port 23 of XSCF. The serial port can also be used as usual.
Switches enabling and disabling of access to XSCF port 8011 (read only port used to reference /dev/console output of the main unit).
Switches enabling and disabling of access to the XSCF port 8010 (XSCF shell port used to remotely control XSCF itself).
For the case that no communication occurs during a given time after login to the XSCF shell, sets the disconnection time as 1 to 255 minutes. The default is "10 minutes."
If 0 is specified, using the automatic disconnection function with a timeout is disabled.