Chapter 2 Machine Administration Functions> 2.5 Hardware Operation Setting Functions

2.5.3 System-related setting function

This function is supported by the PRIMEPOWER250/450 model group, the PRIMEPOWER800/1000/2000 model group, the PRIMEPOWER650/850/900/1500/2500/HPC2500 model group, and the GP7000F model 1000/2000 group. SMC provides the system-related setting function for the PRIMEPOWER800/1000/2000 model group and the GP7000F model 1000/2000 group. Accordingly, use SMC for these model groups.

The system-related setting function makes settings related to operations of the main unit, external power control device, UPS unit, etc.

The table below outlines the system-related functions.

The available menu items depend on the main unit model to be monitored.


For a PRIMEPOWER1/200/400/600 or GP7000F model 200/200R/400/400R/400A/600/600R, see Section 3.1.2, "Main Unit Models and Available Menus."

For a PRIMEPOWER250/450, see Section 3.2.2, "Main Unit Models and Available Menus."

For a PRIMEPOWER650/850/900/1500/2500/HPC2500, see Section 3.3.2, "Main Unit Models and Available Menus."

For a PRIMEPOWER800/1000/2000 or GP7000F model 1000/2000, see Section 3.4.2, "Main Unit Models and Available Menus."

Y : This setting is made at installation of the main unit.

*1: This setting is made as required.

- : No setting to be made.

Function name

Outline

Whether or not a setting is made
(Name(s) of person(s) in charge are enclosed in parentheses.).

Setting the External Equipment Wait Time

When the external power control device is connected to the RCI network, sets the wait time required to prepare the external power control device.

Y
(System administrator)

Setting waiting time for shutdown at power failure

Sets the waiting time that lasts from when the UPS detects a power failure to when it starts operating system shutdown.

Y
(System administrator)

Server CHECK-LED Operation

Turns on the CHECK-LED lamp of the main unit (server) to check the location of the main unit.

When the system-related setting function ends, the CHECK-LED lamp goes off.

-

Warm-up Time Administration

Sets the warm-up time of the main unit.

Setting the warm-up time with the main unit installed in a cold region enables operating system startup after the main unit has become stable.

Y
(System administrator)

Extended Interleave Mode

Sets extended interleave mode.

Extended interleave mode is a function that improves performance in accessing a contiguous area on memory space.

To enable extended interleave mode, it is essential that the system board memory be fully populated, and the capacity of each memory card is equal.

Moreover, to enable the settings, you must also restart the main unit.

When setting extended interleave mode, consult with the customer engineer.

*1
(System administrator/
customer engineer)