Machine Administration Guide 2.6 |
Contents
Index
![]() ![]() |
Chapter 2 Machine Administration Functions | > 2.5 Hardware Operation Setting Functions |
This function is supported by all models except PRIMEPOWER1. SMC provides the RCI-setting function for the PRIMEPOWER800/1000/2000 model group, the PRIMEPOWER900/1500/2500/HPC2500 model group, and the GP7000F model 1000/2000 group. Accordingly, use SMC for these model groups.
The RCI-related setting function makes settings related to the power/environment control interface.
The table below outlines the RCI-related setting functions.
The available menu items depend on the main unit model to be monitored.
For a PRIMEPOWER200/400/600 or GP7000F model 200/200R/400/400R/400A/600/600R, see Section 3.1.2, "Main Unit Models and Available Menus."
For a PRIMEPOWER250/450, see Section 3.2.2, "Main Unit Models and Available Menus."
For a PRIMEPOWER650/850/900/1500/2500/HPC2500, see Section 3.3.2, "Main Unit Models and Available Menus."
For a PRIMEPOWER800/1000/2000 or GP7000F model 1000/2000, see Section 3.4.2, "Main Unit Models and Available Menus."
Y : This setting is made at installation of the main unit.
*1: This setting is made as required.
- : No setting to be made.
Function name |
Outline |
Whether or not a setting is made |
---|---|---|
Displaying a List of RCI Devices |
Displays the RCI status of the main unit and a list of the devices connected to RCI. The following shows the RCI information to be displayed.
|
- |
Confirming the RCI-connected Units |
Blinks the CHECK LEDs of the RCI devices and associates the RCI addresses with the RCI devices. |
- |
Reconfiguring the RCI Network |
When a new RCI device is connected, sets it up in the RCI network. The time required to complete the setting depends on the number of cabinets connected to the network. |
*1 |
Setting the RCI Host Address |
Sets RCI host addresses. Set RCI host addresses so that they are not duplicated. |
*1 |
Initial RCI Network Setup |
Performs initial RCI network setup. The time required to complete initial RCI network setup depends on the number of cabinets connected to the network. |
*1 |
Setting the External Equipment Wait Time |
When the external power control device is connected to the RCI network, sets the wait time required to prepare the external power control device. |
Y |
RCI Device Replacement |
Performs hot swapping of an RCI device. Note that multiple devices cannot be swapped at one time. Note also that the RCI address may not be taken over if there is an INACT device other than the device to be swapped. |
*1 |