9.2 fjmse Driver
WARNING: FJMSE:0002:Can't allocate system resource
- Meaning
- Failed to allocate kernel memory resource used by the fjmse driver.
- Action
- Check kernel memory resource size there might not be enough kernel resources.
WARNING: FJMSE:5000:Inappropriate ioctl for this node
- Meaning
- The fjmse driver received an inappropriate ioctl message for the specified node.
- Action
- Detected an internal error regarding ioctl message. Call a Fujitsu customer engineer.
WARNING: FJMSE:5001:ioctl mismatch
- Meaning
- Detected an internal error regarding ioctl message.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5002:Permission Denied
- Meaning
- Sent an ioctl message using user privileges other than root. The iompadm command might be executed using user privileges other than root
- Action
- Execute the iompadm command using root user privileges.
WARNING: FJMSE:5003:Invalid data size
- Meaning
- The fjmse driver received an ioctl message with inappropriate data size.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5004:Inappropriate path change
- Meaning
- Detected an internal error while the fjmse driver status changes.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5005:Invalid api_level
- Meaning
- The API level of the fjmse driver is not corresponding.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5006:Invalid instance number
- Meaning
- Detected an internal error regarding instance number.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5007:Invalid number of pathname
- Meaning
- Detected an internal error regarding the number of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5008:Inappropriate physical path name
- Meaning
- An inappropriate device name was specified as the physical device name of communication path.
- Action
- Make sure that the specified device name is correct.
Call a Fujitsu customer engineer when there is nothing wrong in the specified device name.
WARNING: FJMSE:5010:Invalid number of instance
- Meaning
- Detected an internal error regarding the number of instance.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5011:Inappropriate Instance Control Node Name
- Meaning
- Detected an internal error regarding name of instance control node.
- Action
- Call a Fujitsu customer engineer.
NOTICE: FJMSE:5012:Path Status is not 'Unconfigured:empty'
- Meaning
- Failed to add a communication path because the communication path has been already added to the IOMP constitution.
- Action
- Use the iompadm command to check the state of communication path.
Call a Fujitsu customer engineer when there is no state of communication path.
WARNING: FJMSE:5013:Lower path info table does not exist
- Meaning
- Detected an internal error regarding control information of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5014:All of path can not be status 'Offline:stop'
- Meaning
- Failed to stop communication paths because all communication paths were going to be changed to "stop" status.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5016:Another process uses this device
- Meaning
- Could not handle a communication path with the fjmse driver since other process was used.
- Action
- Execute the iompadm command again after another iompadm command was completed since the iompadm might be executed in other process.
Call a Fujitsu customer engineer when there is nothing wrong in the process.
WARNING: FJMSE:5017:Upper path info table does not exist
- Meaning
- Detected an internal error regarding control information of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5018:Path status is not 'Offline:stop/fail'
- Meaning
- Detected an internal error with the state other than "stop" or "fail".
- Action
- Use the iompadm command to check the state of communication path.
Call a Fujitsu customer engineer when there is the state "stop" or "fail".
WARNING: FJMSE:5020:Upper path info table already exist
- Meaning
- Constituted again the communication path, which has been already constituted to IOMP constitution.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5021:Could not find Lower Path Info table for /dev/fjse/X
- Meaning
- The communication path "/dev/fjse/X" which is going to be constituted to IOMP constitution does not exist.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5022:Inappropriate ioctl for this path status
- Meaning
- The fjmse driver received an ioctl message, which does not correspond to the state of communication path.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5024:Inappropriate correspondence between upper path info and lower path info table
- Meaning
- Detected an internal error regarding control information of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5026:Inappropriate path number
- Meaning
- The fjmse driver received an ioctl message, which is an inappropriate communication path number.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5027:Can not find corresponding path with Link-ID
- Meaning
- There is no information to link the communication path.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5028:Can not find corresponding path with Path Number
- Meaning
- Detected an internal error regarding control information of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5029:Invalid data type
- Meaning
- There is no data part of an ioctl message, which the fjmse driver received.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5031:Active Path does not exist
- Meaning
- There is no communication path in the state "active".
- Action
- Make sure that the communication path in the state "active" exists.
Call a Fujitsu customer engineer when there is nothing wrong in the state "active".
WARNING: FJMSE:5032:User Access Node does not exist
- Meaning
- The fjmse driver received data from serial ports without opening the User Access Node "/dev/FJSVhwr/mse/a".
The port monitor "ttymon" to "/dev/console" might not be started properly, or the fjmse driver received unnecessary data before the port monitor is started.
- Action
- Make sure that the port monitor has been started, or the communication path is in the state "active."
Call a Fujitsu customer engineer when this trouble is not solved.
NOTICE: FJMSE:5033:Active status path will not exist
- Meaning
- Changed the communication path to the state "stop" without any other communication paths in the state "standby."
- Action
- Login the system via LAN using root user privileges and execute the "iompadm -c fjmse start" command to re-active the console path.
WARNING: FJMSE:5034:Inappropriate data type
- Meaning
- The data form of ioctl messages that sets up the terminal information of "termio(7I)" and etc. is inappropriate.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5035:Inappropriate message for this node
- Meaning
- The fjmse driver received a message of which is not supported to fjmse devices other than User Access Node "/dev/FJSVhwr/mse/a."
- Action
- Devices other than User Access Node are not opened to the public.
Make sure that users access to devices other than User Access Node.
Call a Fujitsu customer engineer when there is nothing wrong on the User Access Node.
WARNING: FJMSE:5036:Trace-mode off, fjmse cannot allocate trace data buffer
- Meaning
- Could not execute the internal logging feature since the fjmse driver cannot allocate memory resource for the internal logging feature.
- Action
- There is nothing wrong to use the system.
Check kernel memory resource size there might not be enough kernel resources.
WARNING: FJMSE:5037:Cannot change to requested path
- Meaning
- Could not change the communication path in the state "active" to another path due to the abnormal state since another path is not in the state "standby."
- Action
- Make sure that a communication path in the state "standby" exists.
Use the iompadm command to enter the state "standby" when communication paths in the state other than "active" are stopped.
Call a Fujitsu customer engineer when this trouble is not solved.
WARNING: FJMSE:5039:Message Classifing Error
- Meaning
- Detected an internal error regarding data classifying.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5040:Invalid path-status
- Meaning
- Detected an internal error regarding status control of communication paths.
- Action
- Call a Fujitsu customer engineer.
WARNING: FJMSE:5041:Free High-Priority Message by unlinking Lower Path
- Meaning
- Detected an internal error regarding delete of the communication path.
- Action
- Call a Fujitsu customer engineer.
NOTICE: FJMSE:5100: Active path change to path -> /dev/fjse/X
- Meaning
- The communication path of "active" status changed to "/dev/fjse/X."
- Action
- If a console message of the se driver such as "/pci@xx,xxxx/ebus@1/FJSV,se@14,400000:b (se#), offline, XXXX Register read error" was displayed before this console message displayed or the status "fail" is displayed after you execute the "iompadm -c fjmse info" command, a hardware error might be occurred. Call a Fujitsu customer engineer.
If there is no console messages of the se driver mentioned above, some error might be occurred between the RS-232C cable and the System Management Console. If you cannot recover by using the following steps, call a Fujitsu customer engineer.
(1) Check the cable connection from the RS-232C cable to the System Management Console.
(2) Execute the "iompadm -c fjmse info" command to display the status.
(3) Change the another communication path which is in the "standby" status to the "active" status by using the "iompadm -c fjmse active" command.
All Rights Reserved, Copyright(C) FUJITSU LIMITED 2005