Enhanced Support Facility 2.6 User's Guide
Contents Index PreviousNext

Part 2 Serial Port Driver Features (PRIMEPOWER800/900/1000/1500/2000/2500/HPC2500 and GP7000F Models 1000/2000)> Chapter 9 Messages

9.1 iompadm Command


 

iompadm: cannot initilize library: Permission Denied

Meaning
The initialization failed because the command was executed using user privileges other than root.
Action
Execute the command using root user privileges.

 

iompadm: cannot initilize library: No Memory

Meaning
The initialization failed due to insufficient memory.
Action
Allocate memory and execute the command again.

 

iompadm: Too many classes specified: Invalid Arguments

Meaning
A class was specified more than once.
Action
Check the format of the command.

 

iompadm: invalid command: Invalid Arguments

Meaning
There is an error in the way a subcommand name was used.
Action
Check the format of the command.

 

iompadm: cannot initilize library: Invalid Path

Meaning
There is no valid Plug-In, or initialization is failed in all the Plug-In.
Action
Make sure that the FJSVse(or FJSVsec) and FJSViomp packages are installed properly.
In the case driver installed properly, call a Fujitsu customer engineer.

 

iompadm: XXX: Invalid Arguments

Meaning
There is an error in the way the specified option, subcommand, or parameter was used.
Action
Check the format of the command.

 

iompadm: XXX: No Memory

Meaning
Insufficient memory occurred during the command execution.
Action
Allocate memory and execute the command again.

 

iompadm: XXX: Invalid Path Number

Meaning
The path was added/deleted to the same class by another process during the command execution.
Action
Execute the command again after completing the job of another process.

 

iompadm: XXX: Invalid Path

Meaning
There is an error in the way the communication path name was specified in the parameter.
Action
Specify a valid communication path name.

 

iompadm: XXX: Too Many Path

Meaning
The communication paths specified in the parameter exceeded the maximum number.
Action
Make sure the number of the target devices specified in the environment setting is not exceeding the maximum number.

 

iompadm: XXX: Not Implemented

Meaning
The specified subcommand dose not support on this product.
Action
Check an available subcommand.

 

iompadm: XXX: Class not Found

Meaning
Could not find a class that corresponds to specified communication path name.
Action
Check the specified communication path name.

 

iompadm: XXX: Not Supported

Meaning
Entered the state, which is not supported by this class.
Action
Check an available subcommand.

 

iompadm: XXX: IO Error

Meaning
The command terminated abnormally.
Action
Check the network equipment (adapter, cables, and switches).
Call a Fujitsu customer engineer when there are nothing wrong with the network equipment.

 

iompadm: XXX: Internal Error

Meaning
The specified interface name does not exist, or the command is not accepted.
Action
Check the specified interface name or subcommand.

 

iompadm: XXX: Invalid Instance

Meaning
There is an error in the way the specified interface name was used.
Action
Check the specified interface name.

 

iompadm: XXX: Class not Found

Meaning
Class name specified by XXX does not exist.
Action
Specify a correct class name.

Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2005