5.1.2 For GP7000F models 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600


 

pwrctrld: Power switch is pressed. Press power switch again within 5 seconds to start shutdown procedure

Meaning
The POWER switch was pressed. Pressing it again within five seconds starts the shutdown process.

 

pwrctrld: power switch ignored.

Meaning
The POWER switch was pressed but was ignored by the scftool(1M) setting.

 

pwrctrld: failed to start (xxx)

Meaning
Could not start the SCF monitoring daemon. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to open pwrctrld pid file.

Meaning
Could not create the PID file.
Action
Check the capacity of the root file system and whether it is mounted in a write-enabled state.

 

pwrctrld: halt system.

Meaning
System shut down due to an error.

 

pwrctrld: failed to start power switch procedure (xxx)

Meaning
Pressing the POWER switch failed to initiate the shutdown procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start UPS AC down procedure (xxx)

Meaning
Failed to initiate UPS switch over procedure when power failed. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start UPS AC recovery procedure (xxx)

Meaning
Failed to initiate UPS procedure after power was restored. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start Power Supply Unit failure procedure (xxx)

Meaning
Failed to initiate power supply failure procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start FAN failure procedure (xxx)

Meaning
Failed to initiate fan failure procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start THERMAL alarm procedure (xxx)

Meaning
Failed to initiate abnormal temperature procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to get SCF dump size

Meaning
Failed to get dump size of SCF driver.
Action
Check the state of the SCF device.

 

pwrctrld: Illegal SCF dump size.

Meaning
The dump size of the SCF driver was 0 or less.
Action
Check the state of the SCF device.

 

pwrctrld: Insufficient memory space for SCF dump

Meaning
Could not get enough memory for the SCF driver dump.
Action
Allocate memory or a swap area.

 

pwrctrld: SCF dump failed

Meaning
The SCF drive dump process failed.
Action
Allocate memory.

 

pwrctrld: /var/opt/FJSVhwr/scf.dump: System call error message

Meaning
Could not create SCF dump file.
Action
Check the /var file system.

 

pwrctrld: cannot write SCF dump file

Meaning
Could not create SCF dump file.
Action
Check the /var file system.

 

pwrctrld: failed to start SCFHALT procedure (xxx)

Meaning
Failed to initiate SCFHALT procedure. xx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start RCI Power Off procedure (xxx)

Meaning
Failed to initiate RCI Power Off procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start Power Off procedure (xxx)

Meaning
Failed to initiate Power Off procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to open /var/opt/FJSVhwr/pwrctrld.lock

Meaning
Could not open the /var/opt/FJSVhwr/pwrctrld.lock file.
Action
Check the /var/opt/FJSVhwr/pwrctrld.lock file.

 

pwrctrld: SCF daemon is already running.

Meaning
SCF daemon is already running.

 

pwrctrld: lockf() failed

Meaning
Failed to get the file to be locked by lockf function.
Action
Check the /var/opt/FJSVhwr/pwrctrld.lock file.

 

/etc/rc0.d/K00FJSVscf: scfreport shutdown was executed.

Meaning
Reported the start of system shutdown to SCF device.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.

 

FJSVscf: The system power down is executed 30 seconds later.

Meaning
The power off of the system is begun 30 seconds later. This message shows the state.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.