Enhanced Support Facility 2.6 User's Guide
Contents Index PreviousNext

Part 1 SCF Driver Features> Chapter 5 Daemon Messages> 5.1 SCF Monitoring Daemon

5.1.1 For PRIMEPOWER 1


 

pwrctrld: Power switch is pressed. Press power switch again within 5 seconds to start shutdown procedure

Meaning
The POWER switch was pressed. Pressing it again within five seconds starts the shutdown process.

 

pwrctrld: power switch ignored.

Meaning
The POWER switch was pressed but was ignored by the scfconf(1M) setting.

 

pwrctrld: failed to start (xxx)

Meaning
Could not start the SCF monitoring daemon. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to open pwrctrld pid file.

Meaning
Could not create the PID file.
Action
Check the capacity of the root file system and whether it is mounted in a write-enabled state.

 

pwrctrld: halt system.

Meaning
System shut down due to an error.

 

pwrctrld: failed to start power switch procedure (xxx)

Meaning
Pressing the POWER switch failed to initiate the shutdown procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start Power Supply Unit failure procedure (xxx)

Meaning
Failed to initiate power supply failure procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start FAN failure procedure (xxx)

Meaning
Failed to initiate fan failure procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start thermal alarm procedure (xxx)

Meaning
Failed to initiate abnormal temperature procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start SCFHALT procedure (xxx)

Meaning
Failed to initiate SCFHALT procedure. xx represents the system call that failed.
Action
Allocate memory or a swap area.

 

pwrctrld: failed to start Power Off procedure (xxx)

Meaning
Failed to initiate Power Off procedure. xxx represents the system call that failed.
Action
Allocate memory or a swap area.

 

/etc/rc0.d/K00FJSVscf: scfreport shutdown was executed.

Meaning
Reported the start of system shutdown to SCF device.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.

 

FJSVscf: The system power down is executed 30 seconds later.

Meaning
The power off of the system is begun 30 seconds later. This message shows the state.
This message might be stored in message log (/var/adm/messages) as "daemon.error". However, it is not abnormal.