3.10 rcinodeadm(1M)

NAME

rcinodeadm - Controls monitoring units connected via RCI

SYNOPSIS

/opt/FJSVhwr/sbin/rcinodeadm address action

AVAILABILITY

FJSVscu

DESCRIPTION

rcinodeadm supports the hot swapping of internal power supply and fan in the External Disk Cabinet connected to the system server via RCI. This command starts/stops the monitoring feature for both devices.
This command also operates fan test and turns off CHECK LEDs when monitoring is restarted.

The following models can use this command.

OPTIONS

address
Specifies addresses of units connected via RCI. You should specify addresses in a format that rciinfo can display (that is 8-digit hexadecimal).

You can specify the following value for action.

disable
Stops monitoring units connected via RCI
enable
Restarts monitoring units connected via RCI

EXAMPLES

# rcinodeadm 003006ff disable
RCI 003006ff: alarm off

NOTES

If the CHECK LED on RCI device is turned on due to self-detection of internal failures, it stays lit after monitoring has restarted.
Note that only the super user can execute this command.

EXIT STATUS

This command returns the following values:

0
Ended normally
>0
Error

SEE ALSO

rciinfo(1M), rcihello(1M)