NAME

scfconf - CUI controlling SCF features

SYNOPSIS

For PRIMEPOWER 1

/opt/FJSVhwr/sbin/scfconf [-p {1|2|off}]

For GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600

/opt/FJSVhwr/sbin/scfconf [-p {1|2|off}] [-c {scf|tod}] [-u time]

AVAILABILITY

FJSVscu, FJSVlscu

DESCRIPTION

scfconf controls the following SCF features:

The following models can use this command.

Power switch settings

Number of times in which power switch until the shutdown beginning is pushed can be set.
The setting can select "1 (one time)", "2 (two times)" or "off(ignore)".
The default setting is "2". After power switch has been pressed twice, the shutdown process is started.

System clock settings

Specifies whether it is preferred to use the system standard clock or to adjust the time of the system standard clock using the SCF high-resolution clock that has a lower degree of error.
The following models can use this setting.
The setting can select "scf" or "tod". The default setting is "tod".
Since system time can be changed by date(1) as well as stime(2), adjtime(2), and settimeofday(3C), you must exercise caution when
using the SCF high-resolution clock. In particularly, do not use the SCF high-resolution clock when running NTP (Network Time Protocol) software that utilizes the network to synchronize time.

UPS operation settings

Specifies the time from power down to the beginning of shutdown.
If power does not come up again within the length of delay, this software will start the shutdown process.
The following models can use this setting.
The delay can be set from 0 second to 9999 seconds. The default delay is 5 seconds.

OPTIONS

The following options are available. If no options are specified, the settings remain unchanged.

-p 1
The system begins shutdown when the power switch is pressed once.
-p 2
The system begins shutdown when a power switch is pressed twice. You must press the power switch again within 5 seconds before the first press is ignored.
-p off
Pressing a power switch is always ignored.
-c scf
Adjusts the time of the system standard clock using the SCF high-resolution clock.
This specification is specifiable with GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600.
-c tod
Only the system standard clock is used.
This specification is specifiable with GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600.
-u time
time: Specifies the length of delay in seconds until this software starts the shutdown process.
This specification is specifiable with GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600.

EXAMPLES

# /opt/FJSVhwr/sbin/scfconf -p off -c scf

NOTES

Only the super user can execute this command.

EXIT STATUS

This command returns the following values:

0
Ended normally
>0
Error

SEE ALSO

scfdate(1M), scftool(1M)