scfconf - CUI controlling SCF features
/opt/FJSVhwr/sbin/scfconf [-p {1|2|off}]
/opt/FJSVhwr/sbin/scfconf [-p {1|2|off}] [-c {scf|tod}] [-u time]
FJSVscu, FJSVlscu
scfconf controls the following SCF features:
The following models can use this command.
Number of times in which power switch until the shutdown beginning is pushed can be set.
The setting can select "1 (one time)", "2 (two times)" or "off(ignore)".
The default setting is "2". After power switch has been pressed twice, the shutdown process is started.
Specifies whether it is preferred to use the system standard clock or to adjust the time of the system standard clock using the SCF high-resolution clock that has a lower degree of error.
The following models can use this setting.
- GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600
The setting can select "scf" or "tod". The default setting is "tod".
Since system time can be changed by date(1) as well as stime(2), adjtime(2), and settimeofday(3C), you must exercise caution when
using the SCF high-resolution clock. In particularly, do not use the SCF high-resolution clock when running NTP (Network Time Protocol) software that utilizes the network to synchronize time.
Specifies the time from power down to the beginning of shutdown.
If power does not come up again within the length of delay, this software will start the shutdown process.
The following models can use this setting.
- GP7000F model 200/200R/400/400A/400R/600/600R and PRIMEPOWER 200/400/600
The delay can be set from 0 second to 9999 seconds. The default delay is 5 seconds.
The following options are available. If no options are specified, the settings remain unchanged.
# /opt/FJSVhwr/sbin/scfconf -p off -c scf
Only the super user can execute this command.
This command returns the following values:
scfdate(1M), scftool(1M)