PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Solaris(TM) Operating System)
Contents Index PreviousNext

Appendix D Notice of supplemental information> D.2 Trouble shooting> D.2.4 Failure occurs during operation (In the case of a Cluster system)

D.2.4.1 Node switching is not executed in Fast switching mode

Phenomenon:

Failover between clusters (job switching between nodes) is not executed in Fast switching mode at cluster operation.

Cause and how to deal with:

In Fast switching mode, it is decided that an error occurred in a transfer route when a response from all other systems in communication was cut off. Therefore, node switching is not executed when all cables are pulled out or when the power of all HUBs is not turned on. When the following message is often displayed, check the cables or HUBs.

unix: NOTICE: SUNW,hme1: No response from Ethernet network : Link Down - cable problem?



Contents Index PreviousNext