PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Solaris(TM) Operating System)
Contents Index PreviousNext

Appendix D Notice of supplemental information> D.2 Trouble shooting> D.2.2 Virtual interface or the various functions of Redundant Line Control function cannot be used

D.2.2.6 Solaris container cannot be started

Symptom
If the virtual interface in fast switching or physical interface in NIC switching is specified for the network setting, the following error message will be output and zone startup will fail:

# zoneadm -z zone0 boot
could not verify net address=192.168.80.10 physical=sha0: No such device or address
zoneadm: zone zone0 failed to verify

or

# zoneadm -z zone0 boot
zoneadm: zone 'zone0': hme0:1: could not bring interface up: address in use by zone 'global': Cannot assign requested address
zoneadm: zone 'zone0': call to zoneadmd failed

Cause and workaround
If the specified interface does not exist in the zone network setting or the IP address same as that specified for the zone network setting, the zone cannot be started. Check if the specified interface or IP address already exists using the "ifconfig(1M)" command.
If you are using NIC switching, check if the method of deactivating the standby interface can be used in the zone. For details, see "7.6 hanetparam Command" and "D.1 Changing Methods of Activating and Inactivating Interface".

image


Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005