PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Solaris(TM) Operating System) |
Contents
Index
![]() ![]() |
Appendix A Messages and corrective actions | > A.1 Messages Displayed by Redundant Line Control function |
In a DR connection script of a Redundant Line Control function, a message is output when not possible to continue communication by disconnecting the corresponding virtual interface and the actual interface due to a certain reason, or when failed to disconnect or connect detecting an error in the workings of a DR connection script. The messages displayed in a DR connection script of a Redundant Line Control function are as follows:
Code |
Message |
Meaning |
Action |
0001 |
When the DR processing is executed for this NIC, the communication is disconnected. The DR processing is stopped. |
When executed a DR process to an interface YY that a virtual interface XX bundles, the communication is disconnected. Stops the DR process. |
Deactivate a virtual interface XX, delete a definition of a virtual interface XX, and execute a DR process again. |
0002 |
The interface is Cluster interface. The DR processing is stopped. |
A virtual interface XX that bundles an interface YY is already registered as the cluster resource. Stops a DR process. |
Delete a definition of the cluster environment and execute a DR process again. |
0003 |
hanetnic command abnormal end. |
Ended abnormally by a hanetnic command (ZZ subcommand) while having a DR process to an interface YY that is bundled into a virtual interface XX. |
Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a DR process again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE). |
0004 |
strptl command abnormal end. |
Ended abnormally by an strptl command while executing a DR process to an interface YY that is bundled into a virtual interface XX. |
Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a strptl command again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE). |
0005 |
stpptl command abnormal end. |
Ended abnormally by an stpptl command while executing a DR process to an interface YY that is bundled into a virtual interface XX. |
Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a DR process again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE). |
0006 |
hanetpoll on command abnormal end. |
Ended abnormally by hanetpoll on command. |
After processed DR, check that the settings of a Redundant Line Control function has no mistake, and execute hanetpoll on command. If an error occurred even after that, check how to deal with the displayed error in a manual and follow the instructions. |
0007 |
hanetconfig modify command abnormal end. |
While processing DR to the interface XX that is bundled into a virtual interface YY, ended abnormally by hanetconfig modify command. |
Check that the settings of a Redundant Line Control function has no mistake. After checked there is no mistake, execute a DR process again. If the same phenomenon occurred even after that, tell Fujitsu SE an error message. |
0008 |
Is the DR processing continued ? |
Do you continue to process DR? |
Input "YES" to continue, "NO" to end. Inputting "YES" into this message to continue DR processing is recommended. |
0009 |
The interface is IPv6 interface. The DR processing is stopped. action=delete interface=YYYY |
A virtual interface that uses an IPv6 address in an interface YYYY exists. Stops DR processing. |
Delete the configuration information that uses an IPv6 address and execute the DR processing again. |
Contents