PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function 4.1 (for Solaris(TM) Operating System)
Contents Index PreviousNext

Appendix A Messages and corrective actions> A.1 Messages Displayed by Redundant Line Control function

A.1.5 DR connection script error output messages

In a DR connection script of a Redundant Line Control function, a message is output when not possible to continue communication by disconnecting the corresponding virtual interface and the actual interface due to a certain reason, or when failed to disconnect or connect detecting an error in the workings of a DR connection script. The messages displayed in a DR connection script of a Redundant Line Control function are as follows:

Code

Message

Meaning

Action

0001

When the DR processing is executed for this NIC, the communication is disconnected. The DR processing is stopped.
devicename=XX interface=YY

When executed a DR process to an interface YY that a virtual interface XX bundles, the communication is disconnected. Stops the DR process.

Deactivate a virtual interface XX, delete a definition of a virtual interface XX, and execute a DR process again.

0002

The interface is Cluster interface. The DR processing is stopped.
action=ZZ devicename=XX interface=YY

A virtual interface XX that bundles an interface YY is already registered as the cluster resource. Stops a DR process.

Delete a definition of the cluster environment and execute a DR process again.

0003

hanetnic command abnormal end.
action=ZZ devicename=XX interface=YY

Ended abnormally by a hanetnic command (ZZ subcommand) while having a DR process to an interface YY that is bundled into a virtual interface XX.

Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a DR process again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE).

0004

strptl command abnormal end.
devicename=XX interface=YY

Ended abnormally by an strptl command while executing a DR process to an interface YY that is bundled into a virtual interface XX.

Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a strptl command again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE).

0005

stpptl command abnormal end.
devicename=XX interface=YY

Ended abnormally by an stpptl command while executing a DR process to an interface YY that is bundled into a virtual interface XX.

Check that there is no mistake in the setting of a Redundant Line Control function. After checked there is no mistake, execute a DR process again. If the same phenomenon occurs, tell an error message to Fujitsu system engineer (SE).

0006

hanetpoll on command abnormal end.

Ended abnormally by hanetpoll on command.

After processed DR, check that the settings of a Redundant Line Control function has no mistake, and execute hanetpoll on command. If an error occurred even after that, check how to deal with the displayed error in a manual and follow the instructions.

0007

hanetconfig modify command abnormal end.
devicename=XX NIC_list=YY

While processing DR to the interface XX that is bundled into a virtual interface YY, ended abnormally by hanetconfig modify command.

Check that the settings of a Redundant Line Control function has no mistake. After checked there is no mistake, execute a DR process again. If the same phenomenon occurred even after that, tell Fujitsu SE an error message.

0008

Is the DR processing continued ?

Do you continue to process DR?

Input "YES" to continue, "NO" to end. Inputting "YES" into this message to continue DR processing is recommended.

0009

The interface is IPv6 interface. The DR processing is stopped. action=delete interface=YYYY

A virtual interface that uses an IPv6 address in an interface YYYY exists. Stops DR processing.

Delete the configuration information that uses an IPv6 address and execute the DR processing again.



Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005