800

line status changed: Link Down at TRUNKING mode (interface on devicename, target=host_name)

An error occurred in the communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) that is operating in the Fast switching mode.

Check whether an error has occurred on the communication path to the remote host system.

line status changed: Link Down at RIP mode (target=host_name)

An error occurred in the communication with the remote host system (host_name).

Check whether an error has occurred on the communication path to the remote host system.

801

line status changed: Link Up at TRUNKING mode (interface on devicename, target=host_name)

The communication with the remote host system (host_name) using the physical interface (interface) controlled by the virtual interface (devicename) is recovered.

No action is required.

line status changed: Link Up at RIP mode (target=host_name)

The communication with the remote host system (host_name) is recovered.

No action is required.

802

file open failed.

Failed to open the file.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

803

file read failed.

Failed to read the file.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

804

pipe create failed.

Failed to create the internal communication pipe.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

805

internal error.

An internal error occurred.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

806

cannot get my process id

Failed to obtain the local process ID.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

814

cannot up interface.

Failed to up the virtual interface.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

815

sha device open failed.

Failed to open the "sha" driver.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

816

ioctl(SHAIOCSETRSCMON) failed.

Failed to send the monitor start request.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

817

ClOpen failed.

The connection to the cluster failed.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

822

no data in cluster event.

No data was found in the cluster event.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

823

ClSetStat failed.

The cluster resource status could not be set.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual of a cluster system as to the materials necessary for examining a cluster system.

824

directory open failed.

Failed to open the directory.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

825

signal send failed.

Failed to send the signal.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

826

command can be executed only with super-user.

The execution-time authority is invalid.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

827

could not allocate memory.

Failed to obtain the memory.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

828

fork failed.

The fork () failed.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

829

child process execute failed.

Failed to generate the child process.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

830

getmsg failed.

Failed to receive the data from the "sha" driver.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

831

shared library address get failed.

Failed to obtain the shared library address.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

832

poll failed.

The poll () failed.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

833

ioctl(SHAIOCSETIPADDR) failed.

Failed to notify the IP address.

Collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

840

polling device name is not defined in configuration information. polling is not started.

The virtual interface name for router monitoring is not defined in the configuration information. Thus, the router monitoring function for this virtual interface cannot be enabled.

Define the virtual interface name for router monitoring in the configuration information. Then, activate the virtual interface and inactivate/activate the router monitoring function.

841

all polling device name is not defined in configuration information. polling is not started.

No virtual interface for router monitoring is defined in the configuration information. Thus, the router monitoring function cannot be enabled.

Define the virtual interface name for router monitoring in the configuration information. Then, activate the virtual interface and inactivate/activate the router monitoring function.

842

device mode is invalid. polling is not started.

The operation mode of a virtual interface for router monitoring is invalid. Thus, the router monitoring function for this virtual interface cannot be enabled.

The operation mode of the virtual interface for router monitoring is defined as Fast switching mode. In Fast switching mode, line monitoring with the router monitoring function cannot be performed. Delete from the monitoring destination information the virtual interfaces whose operation mode is Fast switching mode.

843

polling device is not specified. polling is not started.

No monitoring destination information is specified. Or specified monitoring destination information contains invalid an error. Thus, the router monitoring function cannot be enabled.

Specify the monitoring destination information. Or correct the error in the settings. Then, disable and enable the router monitoring function.

844

polling address is invalid. polling is not started.

The monitoring destination address or host name specified in the monitoring destination information is invalid. Thus, the router monitoring function cannot be enabled.

Correct the monitoring destination address specified in the monitoring destination information. Then, disable and enable the router monitoring function.

845

could not restart in.routed.

Failed to restart the routing daemon. The router monitoring function is stopped and cluster switching is performed.

Check that there is no mistake in the setting of a system, a Redundant Line Control function, and a cluster system. If the same phenomenon occurs, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

846

could not restart in.rdisc.

Failed to restart the router discovery daemon. The router monitoring function is stopped and cluster switching is performed.

Check that there is no mistake in the setting of a system, a Redundant Line Control function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

847

internal error retry over. polling stop.

A router monitoring internal error occurred. The router monitoring is stopped.

Check that there is no mistake in the setting of a system, a Redundant Line Control function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

848

device is inactive. polling stop.

The virtual interface for router monitoring is not activated. The router monitoring function is disabled.

Activate the virtual interface. Then, inactivate and activate the router monitoring function. This message may be displayed when cluster switching occurs during cluster operation, but in this case, no action is needed.

849

poll fail retry over. polling stop.

The transmission line failed as many times as specified by the retry count consecutively. The router monitoring function is disabled.

Check the line failure. After checking the line recovery, inactivate and activate the router monitoring function.

850

cannot down interface.

Failed to inactivate the physical interface.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

851

primary polling failed. lip=logicalIP, target=pollip.

An error of path to the primary monitoring destination was detected in the initial check of the physical interface.

LogicalIP: Logical IP
Pollip: Monitoring destination IP

Check for any failure on the communication path to the monitoring destination.

852

secondry polling failed. lip=logicalIP, target=pollip.

An error of path to the secondary monitoring destination was detected in the initial check of the physical interface. LogicalIP: Logical IP, pollip: Monitoring destination IP

Check for any failure on the communication path to the monitoring destination.

853

phisical interface up failed.

Failed to activate a physical interface.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

854

logical interface up failed.

Failed to activate a logical interface.

Check that there is no mistake in the setting of a Redundant Line Control function and a cluster system. If there is no mistake, collect materials for examination of a Redundant Line Control function, and tell an error message to Fujitsu system engineer (SE).

855

cluster logical interface is not found.

The logical interface registered with the cluster was not found.

Check that there is no mistake in the setting of a system, a Redundant Line Control function, and a cluster system. If the same phenomenon occurrs, collect materials for examination of a Redundant Line Control function and a cluster system, and tell an error message to Fujitsu system engineer (SE). See the manual as to the materials necessary for examining a cluster system.

856

cluster configuration is incomplete.

The logical IP address cannot be activated because the cluster settings are incomplete.

Review the cluster system settings, and reboot the system

857

polling information is not defined.

Monitoring destination information is not defined.

Define monitoring destination information using the hanetpoll command.

858

observe information is not defined.

Monitoring destination information is not defined.

Define monitoring destination information using the hanetobserv command.

859

in.routed is not started.

Routing daemon is not started.

Please change a setup and reboot a system so that /usr/sbin/in.routed is started. (Please check whether a /etc/defaultrouter file exists. If exists, change a file name or delete. Furthermore, please change the file name of /usr/sbin/in.rdisc into /usr/sbin/in.rdisc.saved etc.)

870

polling status changed: Primary polling failed. (ifname,target=pollip)

Line monitoring on the primary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

871

polling status changed: Secondary polling failed. (ifname,target=pollip)

Line monitoring on the secondary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination. If monitoring stopped after checking the recovery of the communication path, make a router/HUB monitoring function invalid and valid using the hanetpoll command. If monitoring fails even though possible to communicate normally, tune the intervals and the number of the times of monitoring, and the time to wait for a linkup with the hanetpoll command.

872

polling status changed: PrimaryHUB to SecondaryHUB polling failed. (ifname,target=pollip)

HUB-to-HUB communication monitoring on the primary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

873

polling status changed: SecondaryHUB to PrimaryHUB polling failed. (ifname,target=pollip)

HUB-to-HUB communication monitoring on the secondary side failed. ifname: Interface name, pollip: Monitoring destination address

Check for any failure on the communication path to the monitoring destination.

874

polling status changed: HUB repair (target=pollip)

Line failure in HUB-to-HUB communication monitoring was repaired. pollip: Monitoring destination address

No action is required.

875

standby interface failed.(ifname)

An error involving standby interface was detected in the standby patrol. ifname: Interface name

Check that there is no error in a transfer route of the standby side. When it takes long time to link up, occasionally a recovery message is output immediately after this message is output. In this case, a transfer route of the standby side is normal. Therefore, not necessary to deal with.

876

node status is noticed.(sourceip:status)

A node status change was notified from the remote system. sourceip: Source address, status: Notified status

Check the status of the source.

877

route error is noticed.(sourceip)

A communication path failure was notified from the remote system. sourceip: Source address

Check for any failure on the communication path to the source.

878

route error is detected.(target=IP)

A communication path failure was detected from the remote system. IP: Remote system address

Check for any failure on the communication path to the source.

879

message received from unknown host.(srcaddr)

A message was received from an unregistered remote system. srcaddr: Source address

Register the corresponding remote host using the hanetobserve command.

880

failed to send node down notice by time out. (dstip)

Node status notification failed due to timeout. dstip: Destination address

Check for any failure of the remote system and on the communication path to the remote system.

881

semaphore is broken. (errno)

Creates a semaphore again because it is deleted.

Not necessary to deal with.

882

shared memory is broken. (errno)

Creates a shared memory again because it is deleted.

Not necessary to deal with.

883

activation of a wrong interface has been detected. (ifname)

Since the interface was unjustly activated by the user, the state of an interface is restored.
ifname: interface name

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the abnormality occurred.

884

unexpected interface deactivation has been detected. (ifname)

Since the interface was unjustly deactivated by the user, the state of an interface is restored.
ifname: interface name

Check that the interface has been recovered correctly. In addition, when this message is displayed to the user operating nothing, please investigate the cause of the abnormality occurred.

885

standby interface recovered.(ifname)

It detected that the route by the side of standby was recovered by standby patrol.
ifname: interface name of standby patrol

Not necessary to deal with.

886

recover from route error is noticed.(ifname)

The recovery was notified from the remote system. ifname: Interface name

Not necessary to deal with.

887

recover from route error is detected. (target=IP)

The recovery of the remote system was detected. IP: Remote system address

Not necessary to deal with.

888

interface is activated. (ifname)

The physical interface was activated. ifname: Interface name

Not necessary to deal with.

889

interface is inactivated. (ifname)

The physical interface was inactivated. ifname: Interface name

Not necessary to deal with.

890

logical IP address is activated. (logicalIP)

The logical IP address was activated. logicalIP: Logical IP

Not necessary to deal with.

891

logical IP address is inactivated. (logicalIP)

The logical IP address was inactivated. logicalIP: Logical IP

Not necessary to deal with.

892

logical virtual interface is activated. (ifname)

The logical virtual interface was activated. ifname: Interface name

Not necessary to deal with.

893

logical virtual interface is inactivated. (ifname)

The logical virtual interface was inactivated. ifname: Interface name

Not necessary to deal with.

894

virtual interface is activated. (ifname)

The virtual interface was activated. ifname: Interface name

Not necessary to deal with.

895

virtual interface is inactivated. (ifname)

The virtual interface was inactivated. ifname: Interface name

Not necessary to deal with.

896

path to standby interface is established. (ifname)

Monitoring by standby patrol started normally.
Ifname: A name of a standby patrol interface.

Not necessary to deal with.

897

immediate exchange to primary interface is canceled. (ifname)

Restrained prompt failback to the primary interface by standby patrol.
ifname: A name of an interface.
This message is output when the monitor-to information to set by a hanetpoll create command is other than HUB.

Not necessary to deal with. When executing prompt failback, use a hanetpoll modify command and change the monitor-to information to a host name or an IP address of HUB.

899

route to polling address is inconsistent.

The network address defined to virtual interface and monitoring target is not the same, or since inappropriate routing information was registered into routing table, the mistaken monitoring is performed.

Please correct, when you check monitoring target address and there is an error. When there is no error in monitoring target address, please check whether inappropriate routing information is registered into the routing table.
When using tagged VLAN interface, please confirm whether a virtual interface is a setting of NIC switching mode (operation mode "d"). If the setting of a virtual interface is NIC switching mode (operation mode "e"), please change the setting of corresponding monitoring information.

[Message number 9xx]

Message number

Message

Meaning

Action

901

failed to takeover logical interface used in zone.

Takeover of the logical interface for the non-global zone failed.

The following causes are suspected:
* The number of logical interfaces reaches the maximum.
* The same IP address is used for two or more interfaces in the system.
* The same IP address is used for the other node and IPv6.Check the network interface and network environment in the system.

902

logical interface of zone was added to a secondaryIF.

The logical interface for the non-global zone was added to the secondary interface.

The secondary interface is set to the network interface of the non-global zone. Changing the interface to the primary interface is highly recommended. However, this will not affect ongoing operations because the logical interface for the non-global zone will automatically be taken over to the primary interface.

903

succeeded in takeover logical interface used in zone.

The logical interface for the non-global zone was succeeded.

Not necessary to deal with.

990

line status changed: all lines disabled: (devicename: interface1=Down, interface2=Down, ...)

In fast switching mode, it is not possible to continue communicating with the other end host because all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down.

Check if or not there is any error in a transfer route of communication to the other end host for all physical interfaces.

991

line status changed: some lines in operation: (devicename: interface1=[Up|Down], interface2=[Up|Down], ...)

In fast switching mode, part of the physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Down (or Up).

Check if or not there is any error in a transfer route of communication to the other end host for physical interfaces in Down status.

992

line status changed: all lines enabled: (devicename: interface1=Up, interface2=Up, ...)

In fast switching mode, all physical interfaces (interfaceN) bundled by a virtual interface in operation (devicename) became Up and communication with the other end host recovered.