In Redundant Line Control function, it is possible to replace or add redundant NIC (PCI card) by linking with Dynamic Reconfiguration (DR) and PCI Hot Plug (PHP). (Keep in mind that Fast Switching mode and NIC Switching mode with defined IPv6 in the virtual interface cannot replace or add NICs)
The following table shows the available functions for replacing or adding NICs (PCI cards), and their support statuses.
Dynamic operation |
Compatible system |
DR(Dynamic Reconfiguration) |
PRIMEPOWER 800/900/1000/1500/2000/2500 and GP7000F model 1000/2000 |
PHP(PCI Hot Plug) |
PRIMEPOWER 450/900/1500/2500/HPC2500 |