Chapter 3 Environment configuration | > 3.6 Setting Option Function | > 3.6.7 Router/HUB monitoring function |
Enable the Router/HUB monitoring function.
Use the "hanetpoll on" command to set up this function. If the "hanetpoll on" command is executed, the ping command is executed on the Router/HUB.
In NIC switching mode, no line failure is assumed even if the ping command fails until the link up wait time (IDLE (seconds) in Figure 3.3) passes. This is because monitoring starts after a physical interface is activated. Time required for link up depends on the HUB type to be connected. If the line monitoring fails although the HUB is not faulty, extend the wait time as required, using the -p parameter of the "hanetpoll on" command.
If the "hanetpoll on" command is executed while the virtual interface with monitoring destination information specified is activated, the router monitoring function is immediately enabled.
If the "hanetpoll" command is executed while the virtual interface with monitoring destination information specified is not activated, the Router/HUB monitoring function is not enabled.
If, after the Router/HUB monitoring function is enabled, the virtual interface with monitoring destination information specified is activated, the Router/HUB monitoring function is not enabled. In this case, disable the Router/HUB monitoring function, activate the virtual interface, and enable the Router/HUB monitoring function again. For more information, see Section "7.7 hanetpoll Command".