PRIMECLUSTER Global Link Services Configuration and Administration Guide: Multipath Function (for Solaris(TM) Operating Environment) |
Contents
![]() |
Appendix B Line Monitoring Daemon |
This section explains the list of console message that the Line Monitoring Daemon output.
[List of the messages]
Message
Description
WARNING: MPNET: mpnetpolld: Not super-user
Meaning
The command failed because an authority other than the super-user tried to activate interfaces.
Workaround
Activate interfaces as super-user.
WARNING: MPNET: mpnetpolld: /etc/opt/FJSVmpnet/conf/switch.conf not found
Meaning
The "/etc/opt/FJSVmpnet/conf/switch.conf" file is not found.
Workaround
Confirm whether the "/etc/opt/FJSVmpnet/conf/switch.conf" file exists. If the file is not found, check whether the patch is applied correctly. If the problem persists, contact your technical support.
WARNING: MPNET: mpnetpolld: /etc/opt/FJSVmpnet/conf/switch.conf cannot open
Meaning
Failed to open the "/etc/opt/FJSVmpnet/conf/switch.conf" file.
Workaround
Confirm whether the "/etc/opt/FJSVmpnet/conf/switch.conf" file exists. If the problem persists, contact your technical support.
WARNING: MPNET: mpnetpolld: cannot find mpnetX interface setting
Meaning
The mpnetX interface setting cannot find in the "/etc/opt/FJSVmpnet/conf/switch.conf" file.
Workaround
Confirm whether the mpnetX interface setting is defined in the "/etc/opt/FJSVmpnet/conf/switch.conf" file correctly.
WARNING: MPNET: mpnetpolld: mpnetX yyy line error (link down)
Meaning
In device yyy of the mpnetX interface, an abnormal transmission path (cable disconnection (Link Down), etc.) was detected.
Workaround
Confirm whether the communication path is connected correctly. After the cause is solved, when the automatic recovery mode is on, the communication path is recovered automatically. Otherwise, the communication path is recovered by using "iompadm recover" command.
WARNING: MPNET: mpnetpolld: mpnetX yyy line error
Meaning
In device yyy of the mpnetX interface, an abnormal transmission path (network failure other than Link Down) was detected.
Workaround
Check the network equipment (adapter, cables, and switches). Recover the mpnetX interface by using the "iompadm recover" command after the cause is solved.
WARNING: MPNET: mpnetpolld: mpnetX: switch (IP: aaa.bbb.ccc.ddd) polling failed
Meaning
Failed to monitor the switch (IP address: aaa.bbb.ccc.ddd).
Workaround
Check whether there is any problem in the switch which the IP address (aaa.bbb.ccc.ddd) is assigned, or in route to the switch. After the cause is solved, the communication path is recovered automatically.
NOTICE: MPNET: mpnetpolld: mpnetX: switch (IP: aaa.bbb.ccc.ddd) polling repair
Meaning
The route to a switch (IP address: aaa.bbb.ccc.ddd) is recovered.
Workaround
Normal operation. No action required.