Description of messages output at the mpnetlinkwatch command and the workaround are explained.
[List of messages]
Message
Description
MPNET: mpnetlinkwatch: Not super-user
Meaning
The command failed because an authority other than the super-user tried to execute.
Workaround
Execute the command as super-user.
MPNET: mpnetlinkwatch: /etc/opt/FJSVmpnet/conf/config not found
Meaning
/etc/opt/FJSVmpnet/conf/config file is missing.
Workaround
Verify the file is installed correctly. Contact your technical support if problem persists.
MPNET: mpnetlinkwatch: /etc/opt/FJSVmpnet/conf/config XXX not found
Meaning
The specified interface name (XXX) is not found in the /etc/opt/FJSVmpnet/conf/config file.
Workaround
Confirm whether the specified interface name is correct or it is defined as /etc/opt/FJSVmpnet/conf/config.
MPNET: mpnetlinkwatch: /etc/opt/FJSVmpnet/conf/config mpnetX illegal media type yyy
Meaning
There is an error in the media type defined in the /etc/opt/FJSVmpnet/conf/config file for the specified interface name (mpnetX).
Workaround
Verify the media type (yyy) of the interface name (mpnetX) defined in the /etc/opt/FJSVmpnet/conf/config file.
MPNET: mpnetlinkwatch: malloc error NNNN
Meaning
An insufficient memory condition occurred while executing this command (NNNN indicates the error information)
Workaround
Increase memory to solve the problem and retry the command again.
MPNET: mpnetlinkwatch: /dev/mpnet open error NNNN
Meaning
The /dev/mpnet file open and the activation failed. (NNNN indicates the error information)
Workaround
Contact your technical support.
MPNET: mpnetlinkwatch: mpnetX yyy illegal
Meaning
There is an error in the device name yyy specified by mpnetX.
Workaround
Verify the specified device name.
MPNET: mpnetlinkwatch: mpnetX yyy line error (link down)
Meaning
For device yyy, a transmission path failure (cable missing (Link Down), etc.) was detected.
Workaround
Check whether the communication path is connected correctly. Restore the MPNET by using the iompadm recover command after the cause is solved.
MPNET: mpnetlinkwatch: ioctl(FIOMPMAXPATHNUM) error NNNN
Meaning
Failed to execute the command for the MPNET driver. (NNNN indicates the error information)
Workaround
Contact your technical support.
MPNET: mpnetlinkwatch: ioctl(FIOMPGETPROP) error NNNN
Meaning
Failed to execute the command for the MPNET driver. (NNNN indicates the error information)
Workaround
Contact your technical support.
MPNET: mpnetlinkwatch: ioctl(MPNIOCLINKDOWN) error NNNN
Meaning
Failed to execute the command for the MPNET driver. (NNNN indicates the error information)
Workaround
Contact your technical support.