PRIMECLUSTER Installation and Administration Guide 4.1 (for Solaris(TM) Operating System)
Contents Index PreviousNext

Appendix D Messages

D.3 Warning Message


 

5100 An error was detected in the failover unit of the line switching unit. (RCI:addr LSU:mask status:status type:type)

Corrective action:

No corrective action is required because processing is retried. If, however, retries fail repeatedly and if this warning occurs frequently, contact your Fujitsu customer engineer (CE).

Supplement

An error was detected in the switching control board of the line switching unit.

addr: Indicates the RCI address of the line switching unit in which an error was detected.

mask: Indicates the LSU mask to be controlled.

status: Indicates the an internal status of the line switching unit by error type.

type: Indicates an error type.

LSU mask value

LSU15 LSU14 LSU13 LSU12 ... LSU03 LSU02 LSU01 LSU00

0x8000 0x4000 0x2000 0x1000 ... 0x0008 0x0004 0x0002 0x0001


Contents Index PreviousNext

All Rights Reserved, Copyright (C) FUJITSU LIMITED 2005