PRIMECLUSTER Global File Services Configuration and Administration Guide 4.1 (Linux)
Contents Index PreviousNext

Appendix A List of Messages> A.2 GFS Shared File System Daemon messages> A.2.2 Error messages

A.2.2.2 MDS(sfcfsmg) daemon


 

ERROR: sfcfs_mds:1001: MDS is failed.

[Explanation]

MDS failed in recovery mounting.

[Response]

Contact your local Customer Support.


 

ERROR: sfcfs_mds:1002: primary MDS is terminated.

[Explanation]

Primary MDS was terminated abnormally.

[Response]

Contact your local Customer Support.


 

ERROR: sfcfs_mds:1003: secondary MDS is terminated.

[Explanation]

Secondary MDS was terminated abnormally.

[Response]

Contact your local Customer Support.


 

ERROR: sfcfs_mds:1004: can't execute primary MDS

[Explanation]

Starting up primary MDS failed.

[Response]

Check following points.

When unsolvable by the above methods, collect the diagnostic data with pclsnap, and contact your local Customer Support.

For details on above commands, see "sfcinfo(8)","sfcrscinfo(8)","sfcgetconf(8)" in this manual. Moreover for the details of the sfcadm(8) command execution line obtained by sfcgetconf(8), see "Backup and restore of the management partition information" in this manual.


 

ERROR: sfcfs_mds:1005: can't execute secondary MDS

[Explanation]

Starting up secondary MDS failed.

[Response]

Check following points.

When unsolvable by the above methods, collect the diagnostic data with pclsnap, and contact your local Customer Support.

For details on above commands, see "sfcinfo(8)","sfcrscinfo(8)","sfcgetconf(8)" in this manual. Moreover for the details of the sfcadm(8) command execution line obtained by sfcgetconf(8), see "Backup and restore of the management partition information" in this manual.


 

ERROR: sfcfs_mds:1006: can't execute MDS

[Explanation]

Starting up MDS failed.

[Response]

Contact your local Customer Support.


 

ERROR: sfcfs_mds:1007: MDS terminated because logreplay failed errcode = errcode

[Explanation]

The log replay by MDS of the file system failed.

[Response]

Contact your local Customer Support.


 

ERROR: sfcfs_mds:1008: fsid: Filesystem status is FSBAD, so MDS can not run. fs_clean = fs_clean

[Explanation]

Starting up MDS failed, because MDS detected a error in file system.

[Response]

Unmount the relevant file system from all of the nodes, and execute sfcfsck(8) specifying -o nolog.


 

ERROR: sfcfs_mds:1009: fsid: MDS terminated abnormally because I/O error occurred continuously on meta-data area of the disk.

[Explanation]

MDS terminated abnormally because I/O error occurred continuously on meta-data area of the disk.

[Response]

To resume the system operation, execute sfcfsck(8) in the full check mode first.

Then back up the file system and correct the hardware failure by replacing the failed disk with a new one, and restore the backed-up data to recover the file system.


Contents Index PreviousNext

All Rights Reserved, Copyright(C) FUJITSU LIMITED 2004