Dynamic Reconfiguration User's Guide 2.5.1
Contents PreviousNext

Chapter 7 Messages and DR Error Conditions on Solaris 9 OS and Solaris 10 OS> 7.1 Command Messages

7.1.4 drcstat error Messages

Message

Usage: drcstat -board [sbXX | all]
Usage: drcstat -board [sbXY | sbXY-N | all] [-xpar]

Usage: drcstat -system [sbXY]
Usage: drcstat -system [sbXY| sbXY-N] [-xpar]

Usage: drcstat -device [sbXY] [-e]
Usage: drcstat -device [sbXY | sbXY-N] [-e] [-xpar]

Cause

Wrong command option

Message

drcstat: Specified system board is not installed.

Cause

Specified system board is not installed.

Remedy

Be sure the specified system board is installed

Message

drcstat: not super user

Cause

Executed command by non super user

Remedy

Execute command by super user

Message

drcstat: dr module is not found.

Cause

DR module cannot be found.

Remedy

Ensure FJSVdr package is properly installed.

Message

drcstat: cannot open /dev/FJSVhwr/pwrctl2: system call error Message

Cause

Cannot access to SCF driver.

Remedy

Ensure SCF driver package is properly installed.

Message

drcstat: ioctl() failed: system call error message

Cause

Displayed "Operation not supported":
This firmware version doesn't support DR.
Displayed "Device busy":
Cannot access to SCF because SCF is busy.
Otherwise:
failed to access to SCF driver.

Remedy

Displayed the "Operation not supported":
Please contact our customer service.
Displayed "Device busy":
Wait for a while and re-execute drcstat.
Otherwise:
Ensure FJSVscd2 package is properly installed.

Message

drcstat: /dev/openprom ioctl() failed :X: system call error message

Cause

Cannot access to openprom.

Remedy

Wait for a while and re-execute drcstat command.

Message

drcstat: malloc() failed.

Cause

Failed to allocate memory

Remedy

Check swap allocation or memory resources and try again.

Message

drcstat: System call failed.

Cause

The system call failed.

Remedy

Check swap allocation or memory resources and try again.

Message

drcstat: dr_info terminated abnormally(X).

Cause

dr_info command failed.

Remedy

Wait for a while and re-execute drcstat command.
Otherwise respond in the manner directed by the system console message

Message

drcstat: Specified system board does not exist in current partition.

Cause

The specified system board does not exist in the current partition.

Remedy

Check the specified system board.

Message

drcstat: DR is not supported.

Cause

1) DR operation was executed with the 32bit Solaris system or older Solaris release such as Solaris 7 OS.

OR

2) DR operation is executed on hardware that does not support DR.

Remedy

For requirements of DR process, please refer to "1.2 DR Requirements"


Contents PreviousNext