C120-B012-10ENZ2(A)
Before using this online manual Preface Chapter 1 Overview of Machine Administration 1.1 The Basics of Machine Administration 1.2 Overview of Machine Administration Functions 1.3 The Machine Administration Menu Chapter 2 Machine Administration Functions 2.1 Hardware Monitoring Functions 2.1.1 Hardware configuration display function 2.1.2 Hardware monitoring information function 2.1.3 Resetting of Monitoring Infomation 2.2 Log Data Function 2.3 Maintenance Guide Function 2.4 Automatic Power Control Function 2.5 Hardware Operation Setting Functions 2.5.1 XSCF setting function 2.5.2 RCI-related setting function 2.5.3 System-related setting function 2.5.4 AP-Net setting/test function 2.6 Firmware Management Function 2.7 Maintenance Program Startup Function 2.8 Other Functions Chapter 3 Model Family-Specific Information 3.1 PRIMEPOWER1/200/400/600,GP7000F model200/200R/400/400R/400A/600/600R 3.1.1 Starting and Exiting Machine Administration Menu 3.1.1.1 Starting Machine Administration Menu 3.1.1.2 Exiting Machine Administration Menu 3.1.1.3 How to read the CUI menu 3.1.1.4 How to read the GUI menu 3.1.2 Main Unit Models and Available Menus 3.1.3 When to Make Settings 3.1.4 Example of Action Taken for Status Changes 3.1.5 Hardware Configuration 3.1.6 Hardware Monitoring Information 3.1.6.1 Monitoring battery life 3.1.6.2 Fan Monitoring 3.1.6.3 Disk Monitoring 3.1.6.4 Tape Unit Monitoring 3.1.6.5 CPU Monitoring 3.1.6.6 Memory Monitoring 3.1.6.7 Power Supply Unit Monitoring 3.1.6.8 UPS Monitoring 3.1.6.9 Degradation Monitoring 3.1.6.10 Setting Monitoring Notification Information 3.1.6.11 Saving/Restoring Hardware Monitoring Information 3.1.7 Log Data 3.1.7.1 Message logs 3.1.7.2 Disk error information 3.1.7.3 Disk Error Statistics Information 3.1.7.4 Memory error information 3.1.7.5 Machine Administration monitoring log 3.1.7.6 SCF error log 3.1.7.7 Thermal error log 3.1.7.8 Fan error log 3.1.7.9 Power error log 3.1.7.10 Power failure and power recovery logs 3.1.7.11 Power log 3.1.7.12 Saving the log data 3.1.7.13 Collecting system information 3.1.8 Hot Swapping Guide 3.1.8.1 The Faulty Hard Disk Drive Replacement (Hot Swap)/Preventive Maintenance of the Hard Disk Drive (Hot Swap)/Include the Hard Disk Drive after the Cold Maintenance 3.1.8.2 Power Supply Unit of Main Cabinet 3.1.8.3 Fan Unit of Main Cabinet 3.1.8.4 Power Supply Unit of Expansion Cabinet 3.1.8.5 Fan Unit of Expansion Cabinet 3.1.9 Auto Power Control System (APCS) Administration 3.1.9.1 Displaying power control relationships 3.1.9.2 Set Schedule 3.1.9.3 Delete Schedule 3.1.9.4 Setting Power Recovery Mode 3.1.9.5 Matching of Cluster Information 3.1.10 RCI-related Settings 3.1.10.1 Display Current RCI Configuration 3.1.10.2 Confirming the RCI-connected Units 3.1.10.3 Reconfiguring the RCI Network (RCI Device Addition) 3.1.10.4 Setting the RCI Host Address 3.1.10.5 Setting the External Equipment Wait Time 3.1.10.6 RCI Device Replacement 3.1.11 Setting Up and Testing the AP-Net 3.1.12 Firmware Administration 3.1.12.1 Disk Firmware Administrator 3.1.13 Diagnostic Program 3.1.14 Remote Setup menu 3.1.15 Setting Management Server Logging 3.1.16 Hardware Information Display Settings 3.1.17 Version Information 3.2 PRIMEPOWER250/450 3.2.1 Starting and Exiting Machine Administration Menu 3.2.1.1 Starting Machine Administration Menu 3.2.1.2 Exiting Machine Administration Menu 3.2.1.3 How to read the CUI menu 3.2.2 Main Unit Models and Available Menus 3.2.3 When to Make Settings 3.2.4 Example of Action Taken for Status Changes 3.2.5 Hardware Configuration 3.2.6 Hardware Monitoring Information 3.2.6.1 Management of Hardware Error Event 3.2.6.2 Monitoring battery life 3.2.6.3 Fan Monitoring 3.2.6.4 Disk Monitoring 3.2.6.5 Tape Unit Monitoring 3.2.6.6 Setting Monitoring Notification Information 3.2.6.7 Notification Test 3.2.7 Log Data 3.2.7.1 Message logs 3.2.7.2 Hardware error log 3.2.7.3 Power log 3.2.7.4 Disk Error Statistics Information 3.2.7.5 Saving the log data 3.2.7.6 Collecting system information 3.2.8 Hot Swapping Guide 3.2.8.1 The Faulty Hard Disk Drive Replacement (Hot Swap)/Preventive Maintenance of the Hard Disk Drive (Hot Swap)/Include the Hard Disk Drive after the Cold Maintenance 3.2.8.2 Power Supply Unit of Main Cabinet 3.2.8.3 Fan Unit of Main Cabinet 3.2.8.4 Power Supply Unit of Expansion Cabinet 3.2.8.5 Fan Unit of Expansion Cabinet 3.2.9 Auto Power Control System (APCS) Administration 3.2.9.1 Start Schedule 3.2.9.2 Stop Schedule 3.2.9.3 Add Schedule Entry 3.2.9.4 Add Holiday 3.2.9.5 Select and Delete Schedule Entries 3.2.9.6 Delete all 3.2.9.7 List Schedule Entries 3.2.9.8 Show Status of Schedule Entries 3.2.10 eXtended System Control Facility (XSCF) Administration 3.2.10.1 Network Configuration 3.2.10.2 User Account Administration 3.2.10.3 Console Administration 3.2.10.4 XSCF Web Administration 3.2.10.5 SNMP Administration 3.2.10.6 Mail Administration 3.2.11 RCI-related Settings 3.2.11.1 Display Current RCI Configuration 3.2.11.2 Confirming the RCI-connected Units 3.2.11.3 Reconfiguring the RCI Network (RCI Device Addition) 3.2.11.4 RCI Device Replacement 3.2.12 System-Specific Administration 3.2.12.1 Setting the External Equipment Wait Time 3.2.12.2 Setting waiting time for shutdown at power failure 3.2.12.3 Server CHECK-LED Operation 3.2.13 Setting Up and Testing the AP-Net 3.2.14 Firmware Administration 3.2.14.1 HCP File Operation 3.2.14.2 Update Firmware of Main Unit 3.2.14.3 Disk Firmware Administrator 3.2.15 Diagnostic Program 3.2.16 Remote Customer Support System (REMCS) Setup menu 3.2.17 Version Information 3.3 PRIMEPOWER650/850/900/1500/2500/HPC2500 3.3.1 Starting and Exiting Machine Administration Menu 3.3.1.1 Starting Machine Administration Menu 3.3.1.2 Exiting Machine Administration Menu 3.3.1.3 How to read the CUI menu 3.3.2 Main Unit Models and Available Menus 3.3.3 When to Make Settings 3.3.4 Example of Action Taken for Status Changes 3.3.5 Hardware Configuration 3.3.6 Hardware Monitoring Information 3.3.6.1 Monitoring battery life 3.3.6.2 Disk Monitoring 3.3.6.3 Tape Unit Monitoring 3.3.6.4 Setting Monitoring Notification Information 3.3.6.5 Saving/Restoring Hardware Monitoring Information 3.3.6.6 Management of Hardware Error Event 3.3.6.7 Displaying and Setting Memory Monitoring Information 3.3.6.8 Displaying and Setting CPU Monitoring Information 3.3.7 Log Data 3.3.7.1 Operating system message log 3.3.7.2 Hardware error log 3.3.7.3 Power log 3.3.7.4 Report log 3.3.7.5 Disk Error Statistics Information 3.3.7.6 Saving the log data 3.3.7.7 Collecting system information 3.3.8 Hot Swapping Guide 3.3.8.1 The Faulty Hard Disk Drive Replacement (Hot Swap)/Preventive Maintenance of the Hard Disk Drive (Hot Swap)/Include the Hard Disk Drive after the Cold Maintenance 3.3.8.2 Power Supply Unit of RCI Device 3.3.8.3 Fan Unit of RCI Device 3.3.9 Auto Power Control System (APCS) Administration 3.3.9.1 Start Schedule 3.3.9.2 Stop Schedule 3.3.9.3 Add Schedule Entry 3.3.9.4 Add Holiday 3.3.9.5 Select and Delete Schedule Entries 3.3.9.6 Delete all 3.3.9.7 List Schedule Entries 3.3.9.8 Show Status of Schedule Entries 3.3.10 RCI-related Settings 3.3.10.1 Display Current RCI Configuration 3.3.10.2 Confirming the RCI-connected Units 3.3.10.3 Reconfiguring the RCI Network (RCI Device Addition) 3.3.10.4 Initial RCI Network Setup 3.3.10.5 Setting the External Equipment Wait Time 3.3.10.6 RCI Device Replacement 3.3.11 UPS Administration 3.3.11.1 Set shutdown delay at power failure 3.3.12 System-Specific Administration 3.3.12.1 Warm-up Time Administration 3.3.12.2 Setting Extended Interleave Mode 3.3.13 Setting Up and Testing the AP-Net 3.3.14 Firmware Administration 3.3.14.1 HCP File Operation 3.3.14.2 Update Firmware of Main Unit 3.3.14.3 Disk Firmware Administrator 3.3.15 Diagnostic Program 3.3.16 Remote Setup menu 3.3.17 Field Support Strategy Solution Tool (FST) Menu 3.3.18 Version Information 3.4 PRIMEPOWER800/1000/2000, GP7000F model1000/2000 3.4.1 Starting and Exiting Machine Administration Menu 3.4.1.1 Starting Machine Administration Menu 3.4.1.2 Exiting Machine Administration Menu 3.4.1.3 How to read the CUI menu 3.4.1.4 How to read the GUI menu 3.4.2 Main Unit Models and Available Menus 3.4.3 When to Make Settings 3.4.4 Example of Action Taken for Status Changes 3.4.5 Hardware Configuration 3.4.6 Hardware Monitoring Information 3.4.6.1 Disk Monitoring 3.4.6.2 Tape Unit Monitoring 3.4.6.3 Saving/Restoring Hardware Monitoring Information 3.4.7 Log Data 3.4.7.1 Message logs 3.4.7.2 Disk error information 3.4.7.3 Disk Error Statistics Information 3.4.7.4 Machine Administration monitoring log 3.4.7.5 Saving the log data 3.4.7.6 Collecting system information 3.4.8 Hot Swapping Guide 3.4.8.1 The Faulty Hard Disk Drive Replacement (Hot Swap)/Preventive Maintenance of the Hard Disk Drive (Hot Swap)/Include the Hard Disk Drive after the Cold Maintenance 3.4.9 UPS Setup 3.4.9.1 Setting waiting time for shutdown at power failure 3.4.10 Setting Up and Testing the AP-Net 3.4.11 Firmware Administration 3.4.11.1 Disk Firmware Administrator 3.4.12 Diagnostic Program 3.4.13 Remote Setup menu 3.4.14 Setting Management Server Logging 3.4.15 Hardware Information Display Settings 3.4.16 Version Information Chapter 4 Command Reference 4.1 addevhost (1M) 4.2 apcscancel (1M) 4.3 apcschmod (1M) 4.4 apcsflush (1M) 4.5 apcsset (1M) 4.6 cmdevsnd (1M) 4.7 diskswap (1M) 4.8 hcpversion (1M) 4.9 hrdconf (1M) 4.10 inst2comp (1M) 4.11 madmin (1M) 4.12 nocheckdev (1M) 4.13 postphp (1M) 4.14 prephp (1M) 4.15 prterrlog (1M) 4.16 prtmadmlog (1M) 4.17 prtmsglog (1M) 4.18 prtpwrlog (1M) 4.19 remcsmain (1M) 4.20 resethardstat (1M) 4.21 savelogs (1M) 4.22 scfconsole (1M) 4.23 scfhttp (1M) 4.24 scfmail (1M) 4.25 scfreset (1M) 4.26 scfshkey (1M) 4.27 scfsnmp (1M) 4.28 scfstat (1M) 4.29 scfuser (1M) 4.30 scslset (1M) 4.31 scslspareset (1M) 4.32 setbattlife (1M) 4.33 setexrdy (1M) 4.34 setexwait (1M) 4.35 setfandly (1M) 4.36 setfanlife (1M) 4.37 setpwrmode (1M) 4.38 setrci (1M) 4.39 setups (1M) 4.40 updateunitinfo (1M) Chapter 5 Messages Appendix A Overall Configuration Diagrams Appendix B Disk Drive Replacement B.1 Outline of disk drive replacement B.2 Flow of Fault Replacement B.2.1 Unmounting disks B.2.1.1 When using SynfinityDisk/GDS B.2.1.2 When using volume management software other than SynfinityDisk/GDS B.2.2 Replacing disk drives B.2.2.1 Hot swap B.2.2.2 Cold swap B.2.3 Mounting disks B.2.3.1 Mounting a disk that has been hot-swapped after automatic unmounting B.2.3.2 Mounting a disk that has been cold-swapped after automatic unmounting B.2.3.3 Mounting a disk that has been hot-swapped after unmounting by means other than GDS B.2.3.4 Mounting a disk that has been cold-swapped after unmounting by means other than GDS B.3 Flow of Preventive Replacement B.3.1 Checking disk error information B.3.2 Unmounting disks B.3.2.1 When using GDS4.1A30 or later B.3.2.2 When using SynfinityDisk/GDS4.1A20 or earlier B.3.2.3 When using volume management software other than SynfinityDisk/GDS B.3.3 Replacing disks B.3.3.1 When using GDS4.1A30 or later B.3.3.2 When using software SynfinityDISK/GDS4.1A20 or earlier B.3.4 Mounting disks B.3.4.1 When using GDS4.1A30 or later B.3.4.2 When using software other than GDS4.1A30 or later B.4 Setting up the GDS Automatic Unmount function B.5 Notes B.5.1 Notes on disks shared by clusters B.6 Messages B.6.1 Error messages displayed during execution of menu items B.6.2 Messages displayed when an error occurs during replacement B.6.3 Messages output to /var/adm/messages Appendix C Troubleshooting C.1 Problems related to SynfinityCluster and PrimeCluster: Appendix D Glossary